Technical data

SPEEDDOME ULTRA 8 CONFIGURATION UTILITY 8200-0600-01, REV. C
OPERATOR’S GUIDE
101 of 138
MegaPower LT
Supported Protocol SensorNet
Maximum Presets 96
Maximum Patterns
(1)
3
DirectSet Menu Yes
(2)
Address Range 1-32
Notes:
(1) Patterns are limited by time and the number of
available dome commands. Total time for each pattern
cannot exceed 6 minutes 50 seconds. Total dome
commands used in all patterns cannot exceed 99.
(2) Requires a compatible keyboard.
MegaPower 48
Supported Protocols SensorNet
RS-422
Maximum Presets 96
(1)
Maximum Patterns
(2)
3
DirectSet Menu Yes
(3)
Address Range 1-48
Notes:
(1) Preset information is stored at the host, not the dome.
(2) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
(3) Requires firmware 1.07 or newer and a compatible
keyboard.
MegaPower 1024/3200/MP CPU
Supported Protocol RS-422
(1)
Maximum Presets 16
(2)
or 60
(3)
Maximum Patterns
(4)
3
DirectSet Menu Not supported
Address Range 1-1024
(5)
, 1-3200
(6)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in
the dome, not the converter.
(4) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64 or
99 cameras is reserved as a global broadcast address.
(6) MegaPower 3200 supports up to 3200.
Performance Notes
The following considerations should be made when using the SpeedDome Ultra 8 camera
dome in a SensorNet or RS-422 environment.
Alarm Action Configuration
The following controllers allow the alarm actions for domes to be specified at the controller:
VM16 Plus/ADTT16/ADTT16E
VM32/AD32/AD32E
VM96
Touch Tracker 16 Elite
AD matrices with AD2083-02A code units
AD168/MP168 with CCM or AD2083-02A.
Do not use both the dome configuration utility and the controller to assign the alarm actions
for the same input. Use only the dome configuration utility or the controller to assign the
alarm actions.