Technical data
SPEEDDOME ULTRA  8 CONFIGURATION UTILITY  8200-0600-01, REV. C 
OPERATOR’S GUIDE
101 of 138 
MegaPower LT 
Supported Protocol  SensorNet 
Maximum Presets  96 
Maximum Patterns 
(1)
 3 
DirectSet Menu  Yes 
(2)
Address Range  1-32 
Notes: 
(1)  Patterns are limited by time and the number of 
available dome commands. Total time for each pattern 
cannot exceed 6 minutes 50 seconds. Total dome 
commands used in all patterns cannot exceed 99. 
(2)  Requires a compatible keyboard. 
MegaPower 48 
Supported Protocols  SensorNet 
RS-422 
Maximum Presets  96 
(1)
Maximum Patterns 
(2)
 3 
DirectSet Menu  Yes 
(3)
Address Range  1-48 
Notes: 
(1)  Preset information is stored at the host, not the dome. 
(2)  Patterns are limited by time and the number of 
available dome commands. Total time for each 
pattern cannot exceed 6 minutes 50 seconds. Total 
dome commands used in all patterns cannot exceed 
99. 
(3)  Requires firmware 1.07 or newer and a compatible 
keyboard. 
MegaPower 1024/3200/MP CPU 
Supported Protocol  RS-422 
(1)
Maximum Presets  16 
(2)
 or 60 
(3)
Maximum Patterns 
(4)
 3 
DirectSet Menu  Not supported 
Address Range  1-1024 
(5)
, 1-3200 
(6)
Notes: 
(1)  Requires the AD2083-02 series code converter. 
(2)  Preset information is stored at the converter, not the 
dome. 
(3)  Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in 
the dome, not the converter. 
(4)  Patterns are limited by time and the number of 
available dome commands. Total time for each 
pattern cannot exceed 6 minutes 50 seconds. Total 
dome commands used in all patterns cannot exceed 
99. 
(5)  Requires additional equipment to achieve these 
numbers. A dome address within each group of 64 or 
99 cameras is reserved as a global broadcast address. 
(6)  MegaPower 3200 supports up to 3200. 
Performance Notes 
The following considerations should be made when using the SpeedDome Ultra 8 camera 
dome in a SensorNet or RS-422 environment. 
Alarm Action Configuration 
The following controllers allow the alarm actions for domes to be specified at the controller: 
•  VM16 Plus/ADTT16/ADTT16E 
•  VM32/AD32/AD32E 
•  VM96 
•  Touch Tracker 16 Elite 
•  AD matrices with AD2083-02A code units 
•  AD168/MP168 with CCM or AD2083-02A. 
Do not use both the dome configuration utility and the controller to assign the alarm actions 
for the same input. Use only the dome configuration utility or the controller to assign the 
alarm actions. 