Installation guide
SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F
INSTALLATION GUIDE 2 of 10
SensorNet Single-Position
J-Box Specifications
REG ID: SV JBOX1
Product Codes
RJ1SNUD .............................120V with North American
line cord
RJ1SNUD-1 ..........................230V with Continental
European line cord
Transformer primary jumpers and mains line cord are
field changeable to support either 120Vac or 230Vac
Electrical
Power source........................100–120Vac or 200–240Vac,
50/60Hz
Fuse......................................3.15A type IEC127, sheet III
Max. operational limits ..........90–135Vac or 180–265Vac,
50/60Hz
Input current..........................1.0A/.5A
Output...................................26Vac, 2.4A max.
Class 2 LPS
Power line protection ............Gas Discharge tube
impulse rated at 8/20µs
impulse discharge current:
10kA
Operational
Diagnostic LEDs ...................Host, aux., dome activity,
noise, power
Power....................................On/Off switch
Compatible with ....................SpeedDome Ultra outdoor
housing
Mechanical
Environment..........................Indoor / Outdoor
Wall mounting options...........concrete, wood, sheet rock
Dimensions (H x W x D)........200 x 200 x 132mm
(7.87 x 7.87 x 5.19 in.)
Mounting area (H x W)..........281 x 200mm (11 x 8 in.)
Weight:..................................3.7 kg (8.25 lbs)
Construction..........................Polycarbonate, non-
metallic enclosure
Color .....................................Light gray
Cover locks ...........................2 quick-release latches
Cable access ........................3 ½-inch NPT strain relief
fittings provided for power,
host, and dome cables.
SensorNet Communication Interface
Cable distance:
J-Box to J-Box..................... 1km (3000ft)
Host to J-Box ...................... 1km (3000ft)
J-Box to camera dome........ Limited by the length of
the low-voltage ac power
cable. See Table 1 on
page 6.
Cable type................................ 1unshielded twisted pair,
22AWG, non-polarized
Surge protection....................... Isolation transformer
coupled, 2000 Vrms, gas
discharge tube impulse
rated at 10kA, 8/20µs,
TVS rated at 1W.
Connectors for host,
aux., and dome ........................ Pluggable Euro-style
Environmental
Weatherproof standard ............ NEMA 4 / IP66
Operating temperature ............. –40°C to 50°C
(–40°F to 122°F)
Storage temperature ................ –10°C to 50°C
(14°F to 122°F)
Relative humidity...................... 0 to 95%
non-condensing
Regulatory
EMC ......................................... 47 CFR, Part 15, Class A
EN55022, Class B
Immunity................................... EN50082-1
Safety....................................... UL1950
CSA 22.2, No. 950
EN60950
See additional declarations on last page.