Specifications
Attaching the Camera Dome to
the Housing
This procedure involves:
• Removing BOTH slot covers from the camera
dome
• Setting the camera address
• Checking the termination jumper on the camera
• Attaching the camera dome to the housing.
A. Remove BOTH slot covers
Note: Perform this procedure on the ground.
WARNING! Proper ventilation requires
slot covers be removed. Otherwise, the
dome could overheat.
1. Slowly turn the eyeball to totally expose one of
the two slot covers.
CAUTION: Turning fast can damage motor
gears.
2. Gently pry the slot cover loose by inserting a
small slotted screwdriver between the slot
cover and the assembly.
3. Slowly turn the eyeball to totally expose the
remaining slot cover. Pry this cover off as well.
CAUTION: With slot covers removed, avoid
touching the camera lens.
B. Set the camera address
At the top of the camera dome are three address
switches. From left to right, set the switches to the
address desired. For example: For address 166,
set SW3 to 1, SW2 to 6, and SW1 to 6.
Protocol address ranges are as follows:
SensorNet 1–255
Manchester 1–64
RS422 1–99
SW3 SW2 SW1
0 9
0 9
0 9
C. Check the termination jumper
Ensure the communication line termination jumper
JW1 is set to “terminated” (pins 2-3). Pins 2-3 are
farthest from 9-pin connector.
Note: A small slotted screwdriver may be used to
pry the jumper loose. Be careful not to damage the
underlying PC board.
!
JW1
RHODUL-03VR/-04VR SPEEDDOME ULTRA VANDAL-RESISTANT OUTDOOR HOUSING 8200-0184-11, REV. A
INSTALLATION AND SERVICE GUIDE
7 of 14