Specifications
Preventing Condensation
Condensation may be eliminated by following
instructions within this guide and observing the
following cautions.
CAUTION: Even small leaks must be
prevented as they can increase humidity
inside the housing.
DO NOT use over seals such as RTV
and silicone caulks.
Ensure fans spin when power is on.
If possible, mount the housing so the
least needed view (such as a wall,
building corner, or pole) is opposite the
fan/heater assembly.
Problems that Can Cause Condensation
Damage, missing parts, or procedures
that most often allow water to enter the housing are
as follows (refer to figures opposite):
Mounts that allow water to enter the air path. If
an older horizontal mount is used, replace it
with a new model or ensure there is ample
slope away from the camera dome and a foam
plug is present
Missing foam seal from entry into the pipe of
the mounting structure
Missing O-ring on end cap, or missing sleeve
or gasket on pipe adapter
Missing Teflon tape around any housing pipe
threads
RTV or similar sealant covering an air path
Loose nuts (4) at the top of the housing
Heater fans not turning
Bent flange on metal housing that
compromises the gasket seal between the
bubble and the housing
Plugged drain holes in the bubble trim ring
Cracked bubble
Tamperproof screws that are missing or
improperly tightened compromise the gasket
seal between the bubble and the housing.
O-ring (inside
end cap)
Foam seal
(inside pipe)
Sleeve (outside),
Gasket (inside
pipe adapter)
Exploded view
Bent Flange
Gasket seal
between
bubble and
metal housing
Nuts (4)
Tamperproof
screws (4)
Heater fans