Appendix A:
Cable Requirements
Data Cable
The table below shows requirements for
SensorNet, RS422, and Manchester networks. For
more information about communication protocols
and cable networks, see Communication Protocols
and Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet RS422 Manchester
Cable type 1
unshielded,
twisted
pair*
2
shielded,
twisted
pair*
1
shielded
twisted
pair**
Wire gauge 22 AWG 22 AWG 18 AWG
Connection Non-
polarized
Polarized Polarized
Max.
devices on
line
32 10 3
* Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables
must be used in indoor ceilings used for environ-
mental air return (called "other air space" in the
National Electrical Code). Order parts through
your distribution network.
Note: If you order cable from an outside
source, wire colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable
(non-plenum) cable is recommended. Plenum-
rated cables must be used in indoor ceilings used for
environmental air return (called "other air space" in
the National Electrical Code). Order
cable directly
from Belden by calling 1-800-235-3361.
Power Cable
The camera dome and housing are to be
connected to a Class 2 LPS, 24Vac, 80VA power
source. Do not exceed the maximum outdoor Class
2 ratings of 30Vac, 100VA.
18AWG 16AWG 14AWG
Low Line Voltage
102/204 Vac
60m
(200ft)
100m
(320ft)
160m
(520ft)
Low Line Voltage
90/180 Vac
30m
(100ft)
50m
(160ft)
80m
(260ft)
Appendix B:
Troubleshooting
This section covers what to do when:
Dome does not respond to commands
Fans do not turn
Picture is grainy or discolored
Poor video
Ice forms on bubble.
Dome Does Not Respond to Commands
Follow steps until the problem is corrected. See
page 9 to order parts.
1. Detach the camera dome from the base and
check the address switches. Are they set
correctly?
- YES: Continue.
- NO: Set the correct address and reconnect
the dome.
2. Verify power is reaching the housing. Press
and hold switch SW2 on the environmental PC
board and observe the green (ac power) LED.
Does the LED glow steadily?
- YES: Reattach the dome and continue.
- NO: Check power at the J-box and ac
cable connections at connector P7 on the
other side of the environmental PC board.
If OK, replace the PC board.
Connector P7 pin outs
Pin Color Description
1 N/A 24Vac
2 N/A Common
3 N/A 24Vac
CAUTION: Use a 2.5mm (0.1in) slotted
screwdriver. Using a blade too wide can
damage connectors.
CAUTION: Screws on the ac connector
are delicate. DO NOT over tighten them!
RHODUL-03VR/-04VR SPEEDDOME ULTRA VANDAL-RESISTANT OUTDOOR HOUSING 8200-0184-11, REV. A
INSTALLATION AND SERVICE GUIDE