5 of 12 
Preventing Condensation 
Damage, missing parts, or procedures 
that most often allow water to enter 
the housing are as follows (refer to 
figures opposite): 
  Mounts that allow water to enter the air path. If 
an older horizontal mount is used, replace it 
with a new model or ensure there is ample 
slope away from the camera dome and a foam 
plug is present 
  Missing foam plug from entry into the pipe of 
the mounting structure 
  Missing O-ring on cover, or missing sleeve or 
seal on end cap assembly 
  Missing Teflon tape around any housing pipe 
threads 
  RTV or similar sealant covering an air path 
  Loose nuts (4) at the top of the housing 
  Heater fans not turning 
  Bent flange on metal housing that 
compromises the gasket seal between the 
bubble and the housing 
  Plugged drain holes in the bubble trim ring 
 Cracked bubble 
  Tamperproof screws that are missing or 
improperly tightened compromise the gasket 
seal between the bubble and the housing 
  Ensure lanyard is not caught between: a) 
flange and trim ring gasket, and b) trim ring 
and sunshield. 
Parts List for Authorized 
Users 
The parts listed below and shown in the exploded 
view can only be ordered by authorized users. To 
become authorized, contact your sales 
representative. 
1.  Housing Assy., 0404-0084-01 
2.  Fan/Heater Assy., 0400-0935-01 
3.  I/O Board with Cable Assy., 0300-2484-02 
4.  Drive, Tamperproof, 1400-0149-01 
5.  Bubble Assy. (Clear), 0404-0083-01 
6.  Bubble Assy. (Smoke), 0404-0083-02 
Exploded view 
Foam seal 
(inside pipe) 
Sleeve (outside), 
Seal (inside end 
cap assembly) 
O-ring (inside 
cover) 
Bent Flange 
Gasket seal 
between 
bubble and 
metal housing 
Tamperproof 
screws (4) 
Nuts (4) 
Heater fans 
1 
2 
3 
4 
5, 6 
Additional shield (not 
shown) used for vandal-
resistant version. 