Operator`s manual
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
7 of 15
Enhanced TOUCH TRACKER with RVQX7X Quad Splitter
COLOR
Orange
1Host A
Yellow 2 Host B
Orange
Auxiliary A
Yellow 4
Auxiliary B
PIN FUNCTION
EIM DB9M
2 Tx
5 Ground
2 Rx
1 Ground
COLOR
Orange
1 SensorNet A
White
228 Vac
Red 3
Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To Dome
Refer to instructions
included with device.
PART QTY PN
DB9 Hood 2 2125-0007-02
DB9 Female contact pins 5 2103-0092-02
DB9 Male contact pins 5 2103-0092-01
DB9 Male Connector 1 2130-0021-01
DB9 Female Connector 1 2130-0022-01
Only one Touch Tracker may
be installed with the Quad
Splitter. This EIM must be
terminated.
TERMINATED
The maximum combined
SensorNet cable length is
1000 m (3000').