Operator`s manual

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
14 of 15
Additional Touch Tracker
Tasks
The following maintenance functions can be
performed using the Touch Tracker. When using
the menus, pressing Zoom selects the first line of
the LCD; pressing Focus selects the second line of
the LCD.
Displaying System Information
This procedure displays system information about the
Enhanced T
OUCH TRACKER being used.
1. Use the number buttons to the select the dome to
reset, and then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the choices
until System Info appears on the LCD.
4. Press Zoom or Focus to select System Info.
5. Press Next or Previous to scroll through the
information.
The LCD displays the following information:
Unit Type: Primary or Secondary
ROM Checksum Values
Calibration information (display should read all
0)
Product Code Flash Version
Product Code EEPROM Version
6. Press Menu to resume camera control mode.
Performing the SensorNet Ping
Test
This procedure tests communications between the
Enhanced T
OUCH TRACKER and domes installed at
your facility.
1. Use the number buttons to the select the dome to
ping then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the choices
until Ping Dome/TTR appears on the LCD.
4. Press Zoom or Focus to select Ping
Dome/TTR.
5. Press Next to start the network test on the
primary or secondary Touch Tracker.
6. Press Menu to exit.
Note: Off-line domes or fixed cameras will generate a
warning beep and not permit the use of the Ping test.
Resetting a Dome
This feature allows you to reinitialize a SpeedDome
or SpeedDome Ultra family camera dome.
1. Use the number buttons to the select the dome
to reset then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the
choices until Reset Dome appears on the
LCD.
4. Press Zoom or Focus to select Reset Dome.
The Enhanced T
OUCH TRACKER sends a request to
the selected dome to reboot. After a brief delay, the
T
OUCH TRACKER resumes camera control mode.
Adjusting V-Phase
Use this procedure to adjust the vertical phase for
cameras installed with your system.
1. Press Menu.
2. Using the Tracker Ball, scroll through the
choices until Adjust V-phase appears on
the LCD.
3. Press Zoom or Focus to select Adjust V-
phase.
4. Press Next or Previous to observe V-phase
through the oscilloscope or Fluke scope.
5. When you are satisfied with the setting, press
Menu to exit.
Note: Off-line domes or fixed cameras will
generate a warning beep and not permit the use of
the V-phase utility.