Operator`s manual

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
13 of 15
Configuring the External
Device
Use this procedure to select the external device
that connects to the Enhanced T
OUCH TRACKER.
1. From the primary Enhanced T
OUCH TRACKER,
press Menu to configure the software for the
external system. The menu appears on the
LCD.
2. Use the Tracker Ball to scroll through the menu
until Config Devices appears on the LCD
screen. Press zoom or focus to select Config
Devices.
3. Press Next to scroll through the available
devices. Refer to the following chart to
determine which device to select.
Device Setting
Use with...
Device
=Mux 16
= POSEM
16-camera Multiplexer and
Intellex
Device
=Mux 9
= POSEM
9-camera Multiplexer
Device
=Mux 4
= POSEM
4-camera Multiplexer, dual page
Quad Splitter, and Quad Splitter
(RVQX7X)
Device
=Quad
= POSEM
Quad Splitter with DB9F-RJ45
connection
Device
=None
Domes connected to dedicated
monitors (no external device).
Device
=PC
For Service use only
4. When the correct configuration appears on the
LCD, press Menu.
Continue with Setting Primary and Secondary
Unit.
Setting Primary and
Secondary Unit
NOTE: Quad Splitter, Intellex 1.x and 2.0, and
stand-alone installations support only one Touch
Tracker.
If you have two Enhanced T
OUCH TRACKERS
installed, one must be designated as Primary; the
other must be designated as Secondary. If you
have only one Enhanced T
OUCH TRACKER installed,
it must be designated as Primary.
1. Press Menu.
2. Using the Tracker Ball, scroll the menu choices
until Tog Primary/2nd appears on the LCD.
3. Press zoom or focus to select Tog
Primary/2nd. Zoom selects the top line; focus
selects the bottom line.
4. Press Next to toggle between setting the
Enhanced T
OUCH TRACKER as primary or
secondary. When the appropriate choice
appears on the LCD, press Menu. The
Enhanced T
OUCH TRACKER will reset.
Repeat this procedure for each Enhanced T
OUCH
TRACKER.