Specifications
MEGAPOWER CPU 8200-0421-01, REV. E
INSTALLATION AND SERVICE GUIDE
20 of 34
ADTTE Controller > MPCPU (2–305 meters (7–1000 feet) maximum at 1200 Baud)
MegaPower CPU Rear View
RS-232 Ports
0650-0991-01
24Vac @ 28VA
Flip Cable
(6003-0047-01)
Note: Set the ADTTE RS-232
baud rate to 1200 (default).
Note: Set the MegaPower
CPU RS-232 baud rate to
1200 (default).
Ethernet Port
Do not connect the RS-232
keyboard to this port.
12Vdc @ 1.25A
ADTTE Controller
6003-0165-01
A B
4 5
5 4
7 7
J3
1
J1 J2
DB9
RJ45
9
0300-1000-01
Pin Description
2 24Vac
3 Gnd
4 24Vac
J3 Connector
A B
Belden 8770 (non-plenum)
Belden 88770 (plenum)
Shield
EIM
Flip Cable
(6003-0047-01)
Note: Connector plugs are supplied to help
reduce the number of terminal boxes used. Using
these plugs, cabling can go directly from box A to
the MPCPU, eliminating box B. See Appendix I
for connection information.