Installation Guide
Table Of Contents
- Warning
- Overview
- Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera
- Network Topology
- Network Connection
- Live View
- Search
- Configuration
- Appendix A - Shutdown Procedure
- Appendix B: Using Media Player to View RTSP Streaming
- Appendix C: Technical Specifications
- Appendix D - Manufacturer and Local Contact Information
- Disclaimer and Regulatory
- EMC Information
- End User License Agreement (EULA)
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration
8200-1953-09 A0 88
Effective Pixels 2592 x 1944
Minimum Illumination
Color .012 Lux @ F2.0
B/W 0.0012 @ F2.0, 0 Lux with IR
Shutter Speed 1 / 30 s - 1 / 10,0000 s
S/N Ratio ≥52 dB
Lens Type Fixed
Focal Length 8mm
Field of View Horizontal 38°,Vertical 27.5°
Lens Mount M12
Video
Video
Compression
H.264 / H.265 / MJPEG
H.264 Compression
Standard
Base Line / Main Profile / High Profile
H.264 Compression
Standard
Main Profile @Leve4.1 High Tier
Resolution
Visible 5MP (2592x1944), 4MP (2592×1520), 2560x1440, 3MP (2304×1296),1080P
(1920×1080), 720P (1280×720), D1 (720x576), 480x240, CIF (352x240)
Thermal 704x576 (Upscaled from 384x288)
Max.Frame Rate
Visible: 30fps @ all resolution.
Thermal: 30fps @ 704x576 (Upscaled)
Video Bit Rate 64 Kbps ~ 5 Mbps
Multiple Streaming Triple stream
Stream 1 (Primary)
50Hz - Stream.1.Resolution
2592x1944|2592x1520|2560x1440|2304x1296|1920x1080|1280x720
60HZ - Stream.1.Resolution
2592x1944|2592x1520|2560x1440|2304x1296|1920x1080|1280x720
Stream 2
(Secondary)
50Hz - Stream.2.Resolution - 1280x720|704x576|352x288
60HZ - Stream.2.Resolution - 1280x720|704x480|352x240
Stream 3 (Third)
50Hz - Stream.3.Resolution - 704x576|480x240|352x288
60HZ - Stream.3.Resolution - 704x480|480x240|352x240
Stream 4 (Thermal)
50Hz - Stream.4.Resolution - 704x576
60HZ - Stream.4.Resolution - 704x480
Bitrate Control VBR / CBR