50 8200-1953-09 A0
• Trigger Email: If “Trigger Email” and “Attach Picture” are checked
(email address must be set first in the Email configuration interface),
the captured pictures and triggered event will be sent into those
addresses.
• Trigger FTP: If “Trigger FTP” is checked, the captured pictures will be
sent into FTP server address. Please refer to FTP configuration
chapter for more details.
7 Select the Save button to save the settings.
- End -
Procedure 38 Schedule an alarm in alarm
1 Select Alarm and Event on the Web User Interface banner and then select Alarm In.
2 Select the Schedule tab.
3 See the Schedule section in the Temperature Measurement Schedule section on page 41 for
assistance.
- End -
Alarm Out
Procedure 39 Enable an Alarm Out alarm.
1 Select Alarm and Event on the Web User Interface banner and then select Alarm Out.
2 Select one of the following from the Alarm Out Mode drop down menu:
• Alarm Linkage: When selected , enter the Alarm Out Name, and
select the Alarm Holding Time and Alarm Type from the drop-down
menus.
• Manual Operation: When selected, select the Alarm Type from the
drop-down menu and select Open to immediately trigger the alarm.
Select Close to stop the alarm.
• Day/Night Switch Linkage: When selected, select the Alarm Type
and then choose to open or close alarm out when the camera switches
to Day mode or Night mode from the drop-down menus.
• Timing: When selected, select the Alarm Type from the drop-down
menu, select Add and then click and drag the mouse on the timeline to
set the schedule of the alarm out. Select Erase and drag the mouse on
the timeline to erase the set time schedule.
3 Select the Save button to save the settings.
- End -
Alarm Server
Procedure 40 Configure the alarm server.
1 Select Alarm and Event on the Web User Interface banner and then select Alarm Server.