Installation Guide

Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration
8200-1953-09 A0 49
4 Select the Alarm Holding Time drop-down menu and select a time.
5 Select the following check box to trigger the alarm.
Alarm Out: If enabled, the alarm output device will be triggered when
detecting abnormal temperature.
6 Select the Save button to save the settings.
- End -
Procedure 36 Enable an alarm when a cable is disconnected
1 Select Alarm and Event on the Web User Interface banner and then select Anomaly.
2 Select the Cable Disconnected tab.
3 Select the Enable check box.
4 Select the Alarm Holding Time drop-down menu and select a time.
5 Select the following check box to trigger the alarm.
Alarm Out: If enabled, the alarm output device will be triggered when
detecting abnormal temperature.
6 Select the Save button to save the settings.
- End -
Alarm In
Procedure 37 Enable an Alarm In alarm.
1 Select Alarm and Event on the Web User Interface banner and then select Alarm In.
2 Select the Enable check box.
3 Select the Alarm Type drop-down menu and select an option.
4 Select the Alarm Holding Time drop-down menu and select an option.
5 Select the Sensor Name text box and enter a name.
6 Select the following check boxes to trigger that alarm:
Alarm Out: If enabled, the alarm output device will be triggered when
detecting abnormal temperature.
Trigger Audio Alarm: If enabled, the warning voice will be triggered
when the temperature exceeds the set value. (Please set the warning
voice first. See Audio Alarm for details)
Trigger Light Alarm: If enabled, the light of the camera will flash
when the temperature exceeds the set value. (Please set the light flash-
ing time and frequency first. See Light Alarm for details)
Trigger SD Snap: If enabled, the system will capture images on
detecting abnormal temperature alarm and save the images on an SD
card.
Trigger SD Recording: If selected, video will be recorded on an SD
card on detecting abnormal temperature alarm.