43 8200-1953-09 A0
Temperature Calibration
In this section you can configure a temperature calibration with or without the blackbody.
Figure 28 Temperature Calibration menu page
Procedure 28 Configuring a temperature calibration with the blackbody
1 Select Temperature on the Web User Interface banner and then select Temperature Cal-
ibration from the menu list.
2 Select the Usage drop-down menu and select Single Face or Multiple Face.
• Single Face Usage = 1 Face at time between .7 and 1 Meter from the
camera at a max rate of 10 to 15 people per minute or one every 4
seconds. (IEC compliant).
• Multi Face Usage = Up to 20 faces at a time between 2 and 6 meters
at a max rate of 200 people per minute or 20 people at a time. (Not IEC
compliant).
3 Select the Ambient Temperature text box and enter the ambient temperature value.
The recommended ambient temperature should be 10~35°C (airless).
4 Select the Ambient Humidity text box and enter the ambient humidity value.
The recommended ambient humidity should be less than 50%.
5 Select the Object Distance text box and enter a value for the distance between the camera
and user.
6 Select the Emissivity text box and enter a value.
For human skin, this value is normally set as 95%.
7 Select the Blackbody drop-down menu and select Open.