8200-1953-09 A0 19
Infrared sources such as sunlight, nearby electrical sources and lighting, should be
minimized to avoid impact on the accuracy of temperature reading.
Airflow should be minimized in the area of the equipment to avoid impact on the
accuracy of temperature detection.
The target of the body surface temperature detection will be the forehead region of the
face. 4 points of 9 pixels each. Three points factored on the center of the forehead
region, then one point left and one point right with fourth point below the center point.