Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Guide
Notice Please read this manual thoroughly and save it for future use before attempting to connect or operate this unit. The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice. Copyright © 2020 Johnson Controls. All rights reserved. JOHNSON CONTROLS, TYCO and ILLUSTRA are trademarks and/or registered trademarks. Unauthorized use is strictly prohibited.
Table of Contents Warning 6 Overview 8 Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera 9 Product overview 9 Installation 9 Calibration / accuracy 16 Guidelines 16 Factors to consider for the environment and installation that can impact measurement 17 Network Topology 20 Network Connection 21 Default IP Address 21 DHCP 22 Live View 24 Face Detection View 26 Search 27 Configuration 31 Image 33 Display Settings 33 Video / Audio 35 On Screen Display
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Anomaly 48 Alarm In 49 Alarm Out 50 Alarm Server 50 Audio Alarm 51 Light Alarm 51 Exception 52 Line Crossing 53 Intrusion 55 Face Detection 57 Target Counting 59 Security 62 User 62 Online User 63 Block and Allow lists 64 Security Management 64 Network 66 TCP/IP 66 Ports 68 Server 68 DDNS 68 IEEE 802.
Reboot 77 Upgrade 77 Log 78 System 79 Basic Information 79 Date and Time 79 Local Config 80 Storage 82 Config 82 Download 84 Appendix A - Shutdown Procedure 85 Appendix B: Using Media Player to View RTSP Streaming 86 Appendix C: Technical Specifications 87 Appendix D - Manufacturer and Local Contact Information 92 Disclaimer and Regulatory 94 Disclaimer 94 Regulatory Information 94 EMC Information End User License Agreement (EULA) 5 96 101 8200-1953-09 A0
Warning • This product is intended to be supplied by a Listed Power Unit, marked with 'Limited Power Source', 'LPS' on unit, output rated minimum 12V/2 A or POE 48V/ 350mA or AC24V (depending on models), no more than 2000m altitude of operation and Tma=60 Deg.C. • Do not attempt to disassemble the camera; in order to prevent electric shock, do not remove screws or covers.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Table 1 Symbols table The following symbols are found on the camera’s product label Refer to instruction manual or booklet Earth (ground) Separate collection for electrical and electronic equipment Complies with provisions of Directive 93/68/EEC Note:Symbols and required information on the product label are legible at 0.75 meter (2.46 feet).
Overview This Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection camera Installation and Configuration Guide is a user manual which provides installation, and configuration information of the camera in Table 2 on Page 8.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera This chapter provides general quick start guide information on the camera and installation procedures. Product overview This chapter included the quick start information guide information and installation procedure of the Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera.
• 2 x Ferrite clamps Contact your dealer if any item is missing. Installation Tools • 1 x Screwdriver • 1 x L-Key hexagonal wrench Quick Reference • Default IP: 192.168.1.168 (DHCP enabled) • Default Username and Password: admin / admin • Power: 12VDC, 2A; PoE 48VDC, 0.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Camera body (Camera buttons and SD card slot are located on the underside of the camera). 7 Note: You will need to remove the cover to access them.
Note:Remove the two screws on the camera cover (1) (Figure 7) to access the buttons. Securely attach the cover when finished. Table 9 Camera button descriptions and SD card slot Number Cable connection description 1 Camera button cover 2 Micro SD Card Slot 3 Reset (Hold for more than 3 seconds) Procedure 1 Mounting the camera to a wall or ceiling 1 Place the mounting template on the surface that you want to attach the camera.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Figure 11 Earth wire connection 9 To power up the camera: • connect a 12V DC power supply to the power connector on the camera cable OR • connect a shielded PoE cable to the ethernet / PoE slot on the camera cable. Note: You must first attach the ferrite ‘rectangle clamp’ around the Ethernet cable (1) (Figure 12).
a Unlock the screw (1) (Figure 13) and pan the camera field of view up to 360 degrees. b Unlock the screw (2) (Figure 13) to tilt the camera body up to 90 degrees. c Unlock the screw (3) (Figure 13) and rotate the camera body up to 360 degrees. Figure 13 Pan, tilt and rotate screws Note:You must securely lock each screw to ensure that the camera holds the modified position. - End - Procedure 4 Mounting the camera to a tripod stand 1 Install the tripod as per the instructions that come with it.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 8 To power up the camera: • connect a 12V DC power supply to the power connector on the camera cable. OR • connect a shielded PoE cable to the ethernet / PoE slot on the camera cable. Note: You must first attach the ferrite ‘rectangle clamp’ around the Ethernet cable (1) (Figure 12). The cable (1) (Figure 12) must loop around the clamp (2) (Figure 12) before the clamp is enclosed.
Figure 15 Multi face usage setup distance recommendations Calibration / accuracy • This device is specified to achieve a +/- 0.3°C accuracy when configured properly following the installation guide and calibrated against a blackbody device. Calibration must be done following device calibration intervals in line with the user manual guidance in order to maintain the specified accuracy.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Elevated skin temperature in the context of use should be confirmed with a secondary evaluation method such as a clinical grade contact thermometer. • The system operator must ensure the face is unobstructed by hair, eyeglasses, and other objects because their presence will interfere with the ability of a measurement thermograph to detect a febrile condition.
• If the camera and/or blackbody are relocated then the customer/user/installer needs to evaluate the new location and ensure it meets the criteria specified in this user manual, such as guidelines, factors to consider, warnings, configuration and calibration steps, environmental, power, air flow, and lighting parameters. • For monitoring, the best temperature measurement distance is: Single Face Usage recommended distance should be 0.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Infrared sources such as sunlight, nearby electrical sources and lighting, should be minimized to avoid impact on the accuracy of temperature reading. • Airflow should be minimized in the area of the equipment to avoid impact on the accuracy of temperature detection. • The target of the body surface temperature detection will be the forehead region of the face. 4 points of 9 pixels each.
Network Topology The Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera delivers video images and audio in real-time using the internet and intranet. It is equipped with an Ethernet RJ-45 network interface. The following images illustrate the network topologies of the camera.
Network Connection Default IP Address Since this is a network-based unit, an IP address must be assigned at the very first bootup. The default IP address of the unit is 192.168.1.168 and sub mask is 255.255.255.0. However, if you have a DHCP server in your network, the unit obtains an IP address automatically from the DHCP server so that you do not need to change the IP address of the camera.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Procedure 5 Connecting from a computer Step Action 1 Ensure the camera and your computer are in the same subnet. 2 Check if the network is available between the unit and the computer by pinging the default IP address. 3 a Start a command prompt. b Type “Ping 192.168.1.168”. If the message “Reply from…” appears, it means the connection is available.
2 Open Microsoft Internet Explorer and enter the URL of the camera as 192.168.1.168. The camera sign in page displays. Note:The computer you use to configure the camera must have an IP address on the same subnet. - End - Procedure 8 Logging on to the camera web user interface Step Action 1 When you select the camera, the sign in page displays. Select your preferred language from the drop-down menu. 2 Enter the username in the Username text box. The default username is admin.
Live View After configuring temperature measurement and face detection, the temperature and face detection results can be viewed on the screen.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Table 20 Live view menu icons and descriptions Icon Description Icon Description Visible light image and thermal image display Face detection indicator Visible light image display SD card recording indicator Thermal image display Color abnormal indicator Start / stop live view Abnormal clarity indicator Start / stop two-way audio Scene change indicator Enable/disable audio Sensor alarm ind
Face Detection View Figure 21 Face Detection view menu Procedure 9 Viewing captured face detection pictures 1 Select the Live button. 2 Select the icon to view a list of all captured faces.
Search You can search for images and recording clips within a specific time and date Figure 22 Search menu Procedure 10 Searching for images locally 1 Select the Search button. 2 Select the Record drop-down menu and select Picture. 3 Select the SD Card drop-down menu and select Local. 4 Select a date in the calendar. 5 Select the first text box under the calendar and enter a start time. 6 Select the second text box under the calendar and enter a finish time.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 2 Select the Record drop-down menu and select Picture. 3 Select the SD Card drop-down menu and select SD Card. 4 Select a date in the calendar. 5 Select the first text box under the calendar and enter a start time. 6 Select the second text box under the calendar and enter a finish time. 7 Select the search icon to view a list of the recordings.
Note:See Table 19 for a list of options available once you have located a recording. - End Table 24 Options available after you locate a recording Icon Description Icon Description Play button. After pausing the video, click this button to continue playing. Pause button Stop button Speed down Speed up Watermark display Enable / disable audio; drag the slider to adjust the volume after enabling audio. Procedure 13 Searching for recordings on the SD card 1 Select the Search button.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 6 Select the icon to download the video file in the PC. • Select the Set up button to set the storage directory of the video files. • Select the Open button to play the video. • Select the Clear List button to clear the downloading list. • Select the Close button to close the downloading window.
Configuration The following sections explain how you can configure the Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera using the Web User Interface. Accessing the Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Web User Interface Use the following procedure to access the camera Web User Interface. Use Internet Explorer 11 web browser.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Changing the Camera Web User Interface Language Use the following procedure to change the language used in the camera Web User Interface. Procedure 16 Change the Camera Web User Interface Language Step Action 1 Open the camera sign in page. If you are already logged in to the Web User Interface, select Log Off to display the sign in page.
Image In this section you can configure the display settings, video and audio, on-screen display, video mask and regions of interest. Figure 25 Image settings menu page Display Settings In this section you can adjust the camera parameter settings and schedule image parameters settings. Procedure 17 Adjusting the camera parameters 1 Select Image on the Web User Interface banner to view the Camera Parameters tab.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Saturation: Set the degree of color purity. The purer the color, the brighter the image is. • Sharpness: Select the Sharpness check box and then set the resolution level of the image plane and the sharpness level of the image edge. • Noise Reduction: Select the Noise Reduction check box and set the noise reduction value. Decrease the noise and make the image more thorough.
Note:Select Cancel to undo any changes. - End - Procedure 18 Scheduling when certain camera parameters should be used 1 Select Image on the Web User Interface banner to view the Camera Parameters tabs. 2 Select the Schedule tab to view the schedule menu. 3 Select the Schedule drop-down menu and one of the following: • Full Time for common, day, night mode • Timing to enter a time. Note:When Timing is selected then you must click and drag the Timing Range slide-bar to enter the time.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 7 Select the Video Quality drop-down menu and select an option. The higher the image quality then more bitrate will be required. Note:This option is only available when VBR is selected in step 5. 8 Select the I Frame Interval text box to enter a value for the I frame. Note:I frame determines how many frames are allowed between a “group of pictures”.
When “Talkback” is selected, the external audio output device will be used to output sound for two-way talk. When “Warning” is selected, the external audio output device will be used to output the pre-defined audio alarm. 7 Select the Speaker drop-down menu and select the following: • Warning When “Talkback” is selected, the built-in speaker will be used to output sound for two-way talk. When “Warning” is selected, the built-in speaker will be used to output the pre-defined audio alarm.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Video Mask A maximum of four video masks can be setup. Procedure 23 Adding a video mask 1 Select Image on the Web User Interface banner to view the View Mask option in the menu list. 2 Select the Video Mask option to view the Video Mask menu. 3 Select the Enable check box to enable a video mask. 4 Select the Draw Area button and then drag the mouse over the video and draw the video mask.
Temperature In this section you can set the temperature and an alarm type and schedule when the temperature measurement should be performed. Figure 26 Temperature settings menu page Temperature measurement In this section you can set the temperature and an alarm type. Procedure 25 Configuring temperature measurements 1 Select Temperature on the Web User Interface banner to view the Detection Config tab. 2 Select the Enable check box to enable temperature measurement.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Note:When the body temperature measured is higher or lower than the set value, it will trigger alarms. 6 Select the Alarm Holding Time drop-down menu and select an option. 7 Select the following check boxes to trigger that alarm: • Alarm Out: If enabled, the alarm output device will be triggered when detecting abnormal temperature.
Temperature measurement schedule In this section you can schedule when the temperature measurement should be performed. Figure 27 Temperature measurement schedule menu page Procedure 26 Adding a weekly temperature schedule You can set the alarm time from Monday to Sunday for a single week. Each day is divided in one hour increments. Blue in Figure 22 means scheduled. No colour means that its unscheduled. 1 Select Temperature on the Web User Interface banner to view the Detection Config tab.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 2 Select the Schedule tab to view the schedule menu. 3 Select the Date text box and enter a date. 4 Select Add for any day to schedule the temperature measurement and then click and drag the mouse over the timeline to set the time. Or Select Manual Input for any day to select a specific start and end time. This adds more granularities (minutes).
Temperature Calibration In this section you can configure a temperature calibration with or without the blackbody. Figure 28 Temperature Calibration menu page Procedure 28 Configuring a temperature calibration with the blackbody 1 Select Temperature on the Web User Interface banner and then select Temperature Calibration from the menu list. 2 Select the Usage drop-down menu and select Single Face or Multiple Face. • Single Face Usage = 1 Face at time between .
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Note:A red box is now visible in the thermal image window. See example in Figure 28. The blackbody should not be visible within this area for accuracy measurement. If the blackbody is outside of the box then move it within the box. Note:It is important that the blackbody is in a position where it will not be obscured during detection.
Note:The Blackbody target icon will not update the read temperature value until the page is refreshed or the target icon is repositioned within the Blackbody. Note:It may take up to 10 minutes to make the temperature module of the camera stable. Therefore, please measure the body temperature after 10 minutes. Note:The Blackbody does not support IP40. If the blackbody is used with the camera, it shall be installed 2 or 3 meters away from the camera. It cannot be blocked.
Alarm and Event In this section you can configure motion detection, an SD card, alarm in and out, the alarm server, audio alarm, light alarm, set the camera to detect changes in the surveillance environment affected by the external factors, the sensitivity the system responds to the amplitude of the scene change, trigger alarms and set areas of interest.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Trigger Snap: If selected, the system will capture images on motion detection and save the images on an SD card. • Trigger SD Recording: If selected, video will be recorded on an SD card on motion detection.
Anomaly In this section you can take an action, such as triggering an alarm, if the SD card is full, has an error or if the camera experiences some error such as the IP collision or cable disconnection. Procedure 33 Enable an alarm when the SD Card is full 1 Select Alarm and Event on the Web User Interface banner and then select Anomaly. 2 Select the Enable check box. 3 Select the Alarm Holding Time drop-down menu and select a time.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 4 Select the Alarm Holding Time drop-down menu and select a time. 5 Select the following check box to trigger the alarm. • Alarm Out: If enabled, the alarm output device will be triggered when detecting abnormal temperature. 6 Select the Save button to save the settings.
• Trigger Email: If “Trigger Email” and “Attach Picture” are checked (email address must be set first in the Email configuration interface), the captured pictures and triggered event will be sent into those addresses. • Trigger FTP: If “Trigger FTP” is checked, the captured pictures will be sent into FTP server address. Please refer to FTP configuration chapter for more details. 7 Select the Save button to save the settings.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 2 Select the Server Address text box and enter the server address. 3 Select the Port text box and enter the port number. 4 Select the Heartbeat drop-down menu and select an option. 5 Select the Heartbeat Interval and enter a number. 6 Select the OK button to save the settings.
3 Select the Flashing Frequency drop-down menu and select and option: • Low • Middle • High 4 Select the OK button to save the settings. - End - Exception This function can detect changes in the surveillance environment affected by the external factors. Procedure 44 Configuring an exception detection. 1 Select Alarm and Event on the Web User Interface banner and then select Exception.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Procedure 45 Configuring an exception detection sensitivity The higher the value is, the more sensitive the system responds to the amplitude of the scene change. 1 Select Alarm and Event on the Web User Interface banner and then select Exception. 2 Select the Sensitivity tab. 3 Move the slide-bar to increase or descrease the sensitivity. 4 Select the Save button to save the settings.
Note:These three types of objects can be selected simultaneously. Please select the detection objects as needed. If no object/target is selected, alarms will not be triggered even if line crossing detection is enabled. 6 Select the Alarm Holding Time drop-down menu and select an option. 7 Select the following check boxes to trigger that alarm: • Alarm Out: If enabled, the alarm output device will be triggered when detecting abnormal temperature.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Note:A<-B: The alarm will be triggered when the intruder/vehicle crosses over the alarm line from B to A. 5 Select the Draw Area button and click and drag the mouse over the video to draw a line on the image. Note:Select the Clear button to delete the lines. 6 Select the Save button to save the settings.
• Human: Alarms will be triggered if someone crosses the pre-defined alarm lines. • Motor Vehicle: Alarms will be triggered if a vehicle with four or more wheels (eg. a car, bus or truck) crosses the pre-defined alarm lines. • Motorcycle/Bicycle: Alarms will be triggered if a non-motor vehicle (eg. a motorcycle or bicycle) crosses the pre-defined alarm lines. Move the slide-bar to increase or descrease the sensitivity. Note:These three types of objects can be selected simultaneously.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Select the Stop Draw button to stop drawing. Select the Clear button to delete the alarm area. 5 Select the Save button to save the settings. - End - Procedure 51 Schedule an Intrusion alarm 1 Select Alarm and Event on the Web User Interface banner and then select Intrusion. 2 Select the Schedule tab.
• Alarm Out: If enabled, the alarm output device will be triggered when detecting abnormal temperature. • Trigger Audio Alarm: If enabled, the warning voice will be triggered when the temperature exceeds the set value. (Please set the warning voice first. See Audio Alarm for details). • Trigger Light Alarm: If enabled, the light of the camera will flash when the temperature exceeds the set value. (Please set the light flashing time and frequency first.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Note:For example, if 5 seconds is selected, the camera will capture the same target once every 5 seconds during its continuous tracking period. 4 Select the Snapshot Number check box and enter a number in the text box. Note:For example, if the snapshot number is enabled and set (eg.
Note:To save snapshots to the local PC, please enable “Local Smart Snapshot Storage” in the local config interface first. To save snapshots to the SD card, please install an SD card first. 5 Select one of the following Detection Target check boxes to enable an alarm: • Human: Alarms will be triggered if someone crosses the pre-defined alarm lines. • Motor Vehicle: Alarms will be triggered if a vehicle with four or more wheels (eg. a car, bus or truck) crosses the pre-defined alarm lines.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 6 Set the detectable face size by defining the maximum value and the minimum value in the Min and Max text boxes. (The default size range of a single face image occupies from 3% to 50% of the entire image). 7 Optional - Select the Statistics check box to enable Statistics • If enabled, you can see the statistical information in the live view interface.
Security In this section you can add, delete and modify users and assign them permissions. You can see who is using the camera. An administrator can remove all the other users (including other administrators). An administrator can block a user and or give them access to the camera. In order to prevent against malicious password unlocking, the 'locking once illegal login' function can be enabled. If this function is enabled, then after six unsuccessful login attempts the login interface locks.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Advanced User: User has the same permissions as an Administrator except for; user, backup settings, factory reset, and upgrading the firmware. 7 Select the Bind MAC check box and enter the MAC Address. When this option is enabled, only the PC with the specified MAC address can access the camera for that user. 8 Select the OK button to save the settings.
2 Select the Kick-off button for any user to remove them. - End - Block and Allow lists An administrator can block a user and or give them access to the camera. Procedure 63 Blocking or enabling a user access 1 Select Security on the Web User Interface banner and then select Block and Allow from the menu list. 2 Select the Enable address filtering check box. 3 Select the Block the following address option to block the user. Or Select the Allow the following address option to allow the user access.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Medium Level: 9~15 characters, including at least two of the following categories: numbers, special characters, upper case letters, lower case letters. • Strong Level: 9~15 characters. Numbers, special characters, upper case letters and lower case letters must be included. Note:For your account security, it is recommended to set a strong password and change your password regularly.
Network In this section you can configure the IPv4, IPv6 and PPPoE settings on the camera. If PPPoE is used to connect to the internet, the camera receives a dynamic WAN IP address. This IP address changes frequently. To be notified, the IP change notification function can be used. You can also configure settings for the ports, server, DDNS, 802.1x, RTSP, UPnP, Email, FTP, HTTPS, Spvmn and Quality of Service (QoS).
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 3 d Enter the Gateway IP address in Gateway text box xxx.xxx.xxx.xxx. e Enter the Preferred DNS Server IP address in the Preferred DNS Server text box. f Enter the Alternate DNS Server IP address in the Alternate DNS Server text box. Select the Save button to save the settings.
4 Select the Save button to save the settings. - End - Ports In this section you can configure the ports. Procedure 71 Configuring the HTTP, HTTPS, Data and RTSP ports 1 Select Network on the Web User Interface banner and then select More. 2 Select the HTTP Port text box and a number. The default HTTP port is 80. It can be changed to any port which is not occupied. 3 Select the HTTPS Port text box and a number. The default HTTPs port is 443. It can be changed to any port which is not occupied.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration DHCP and DNS service and the user wants only to access their camera within their own network. By default, when making a DHCP request the camera transmits its hostname as part of the DHCP request. This option is not user configurable. The cameras hostname matches the configurable parameter “camera name” on the Web User Interface.
Procedure 75 Viewing RTSP Stream through media player 1 Select Network on the Web User Interface banner and then select More. 2 Select the RTSP tab. 3 Select the Enable check box to enable RTSP configuration. 4 Select the Port text box and enter the access port of the streaming media. The default number is 554. 5 Select the Address text box and enter RTSP address (unicast) format that can be used to play the stream in a media player. 6 Select the Save button to save the settings.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Note:When playing the video through the multicast streams in a VLC player, please pay attention to the mode of the VLC player. If it is set to TCP mode, the video cannot be played. Note:If the coding format of the video of the main stream is MJPEG, the video may be disordered at some resolutions.
When different alarms are triggered at the same time, multiple emails will be sent separately. 10 Select the Test button to test the connection of the account. 11 Select the Receipent Address text box and enter the receipents e-mail address and then select the Add button. 12 Select the Save button to save the settings. - End - FTP After an FTP server is set up, captured pictures from events will be uploaded to the FTP server.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration 3 Select the FTP settings that you want to delete. 4 Select the Delete button. 5 Select the Save button to save the settings. - End - Procedure 82 Testing FTP server settings 1 Select Network on the Web User Interface banner and then select More. 2 Select the FTP tab. 3 Select the FTP server settings in the list and then select the Test button. 4 Select the Save button to save the settings.
Select the Create a private certificate option and then select the Create button to create a private certificate and enter the following: • Country (only two letters available). • Domain (camera’s IP address/domain). • Validity date • Password • Province/state • Region 5 Select the Save button to save the settings. - End - Procedure 85 Request an HTTPS certificate 1 Select Network on the Web User Interface banner and then select More. 2 Select the HTTPS tab.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration • Install Address • Valid Time • Heatbeat Period • Number of Heartbeat Timeout • Alarm Channel ID • Video Channel ID • Talk Channel ID 4 Select the Save button to save the settings. - End - Quality of Service (QoS) QoS (Quality of Service) function is used to provide different quality of services for different network applications.
Maintenance In this section you can import and export settings from one camera to another, reboot the camera, update the camera firmware and view and export log information. Figure 33 Maintenance settings menu page Backup and Restore You can import and export settings from one camera to another. Procedure 88 Importing settings from one camera to another 1 Select Maintenance on the Web User Interface banner to view the Backup and Restore tab.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Select the Export Temp Data button to export the temperature data. 3 Select the Save button to save the settings. - End - Procedure 90 Restore settings to their factory default state 1 Select Maintenance on the Web User Interface banner to view the Backup and Restore tab.
Note:Do not close the browser or disconnect the camera from the network during the upgrade. - End - Procedure 94 Updating the Novatel thermal driver You can update the Novatel thermal driver. 1 Select Maintenance on the Web User Interface banner and then select Upgrade. 2 Select the Browse button and navigate to the upgrade file. 3 Select the Upgrade button to start upgrading the Novatel thermal driver. The device restarts automatically.
System In this section you can view the following system information, Device Name, Model, Product Code, Brand, Software Version, Software Build Date, Kernel Version, Hardware Version, Onvif Version, Temperature Version, Video Structured Version, Face Detection Version, OCX Version and MAC.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Procedure 97 Selecting a time zone and enabling daylight saving time 1 Select System on the Web User Interface banner to view the Date and Time option in the menu list. 2 Select Date and Time to view the Zone tab menu. 3 Select the Zone drop-down menu and select a time zone. 4 Select the DST check box to enable DST. 5 Select Auto DST to automatically select the DST.
5 Select the Audio Recording 'Open' or 'Close' option. 6 Select the Bitrate Overlay 'Open' or 'Close' option. 7 Select the Local Smart Snapshot Storage 'Open' or 'Close' option. 8 Select the Save button to save the settings.
Storage In this section you can eject or format the SD Card and divide space up on the SD card between snapshots and videos. You can set recording parameters and schedule the recording date and time. You can set the format, resolution and quality of the image saved on the SD card, the snapshot interval, quantity and snapshot timing.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Procedure 100 SD Card Management 1 Select Storage on the Web User Interface banner to view the Management tab. 2 You can format or Eject the SD card. a Select the Format button to format the SD card. All data is cleared by selecting this button. a Select the Eject button to stop writing data to SD card. Then the SD card can be ejected safely.
Procedure 103 Configure offline recording settings 1 Select Storage on the Web User Interface banner and then select the Offline Record Settings tab. 2 Select the Enable check box to enable offline record settings. 3 Select the NVR IP Address text box and enter the IP address. 4 Select the Pre Record Time text box and enter a number. 5 Select the Record Delay text box and enter a number. 6 Select the Save button to save the settings.
Appendix A - Shutdown Procedure The following steps are a guideline to shutdown the thermal imaging system. 85 1 Stop the flow of people past the camera. 2 Log off the camera Web User Interface. 3 Remove power (12VDC or PoE) from the camera. 4 Remove power from the blackbody.
Appendix B: Using Media Player to View RTSP Streaming Note:This appendix is provided for user instruction only. Tyco Security Products does not support or is not responsible for any error caused during the use of third party software used for RTSP playback. Procedure 105 Procedure 106 Viewing RTSP Stream through Media Player Step Action You can use Media Player to view live video in real time from the camera. 1 Select Media then Open Network Stream.
Appendix C: Technical Specifications The table below lists technical specifications of the Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection camera.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Effective Pixels 2592 x 1944 Color .012 Lux @ F2.0 Minimum Illumination B/W 0.0012 @ F2.0, 0 Lux with IR Shutter Speed 1 / 30 s - 1 / 10,0000 s S/N Ratio ≥52 dB Lens Type Fixed Focal Length 8mm Field of View Horizontal 38°,Vertical 27.5° Lens Mount M12 Video Video Compression H.264 / H.265 / MJPEG H.264 Compression Standard Base Line / Main Profile / High Profile H.
Quality Control 5 levels under VBR; Freely adjustable under CBR Image Setting ROI, Saturation, Brightness, Chroma, Contrast, Wide Dynamic, Sharpen, NR. Audio Audio Communication 1CH audio input; 1CH built-in speaker Audio Compression Format G .711A, G.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Response Time Less than 50ms Calibration Automatic calibration with Blackbody Accuracy ±0.5°C with Blackbody calibration, over the range of 30 C to 42 C Network Network Protocol TCP / IP, UDP, DHCP, NTP, RTSP, PPPoE, DDNS, SMTP, FTP, SNMP, UPnP, Unicast, Multicast Cyber Security HTTPS / IP Filter / IEEE 802.
Blackbody Calibrator Temperature Range 20.0°C to 70.0°C (68°F to 158°F) Emissive Area 100mm x 100mm Display Resolution 0.01°C (0.0018°F) Radiance temperature expanded uncertainty ± 0.25°C between 33°C and 40°C (± 0.45°F between 91.4°F and 104°C) Stability ± 0.03°C (± 0.09°F) Emissivity 0.96 IPT05-B29-BNDA3 includes a 110V 60Hz blackbody. Power Supply IPT05-B29-BN2A3 includes a 220V 50Hz blackbody.
Appendix D - Manufacturer and Local Contact Information The term manufacturer is defined as follows based on IEC 60601-1:2005 +A1:2012. "natural or legal person with responsibility for the design, manufacture, or labeling of the medical system, assembling a medical system, or adapting medical system, regardless of whether these operations are performed by that person or on that person's behalf by a third part.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Israel (+972-772 201 350) France (0800 90 79 72) Italy (+39-0230 510 112) Ireland (1800943570) Denmark (+45-4494 9001) Greece (00800-312 294 53) Turkey (00800-31923007) South Africa (+27 (0) 10 100 3292) Oman ((00) 80074364) KSA +9668008500509 Spain (900 99 31 61) Germany (0800 1806 757)) Belgium (0800 76 452) Bahrain ((0)800-04127) Russia 81080020521031 Nordic (04494 9001)
Disclaimer and Regulatory Disclaimer With regard to the product with internet access, the use of product shall be wholly at your own risks. Our company shall not be responsible for abnormal operation, privacy leakage or other damages resulting from cyber attack, hacker attack, virus inspection, or other internet security risks; however, our company will provide timely technical support if necessary. Surveillance laws vary from country to country.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Directive 94/62/EC: The Directive aims at the management of packaging and packaging waste and environmental protection. The packaging and packaging waste of the product in this manual refers to must be disposed of at designated collection points for proper recycling and environmental protection.
EMC Information • ME system is not specified for use only in a shielded location. • (Need statement(s) of the environments for which the ME system is suitable.) • Essential performance of the medical system exists when video monitoring is carried out in the designated area to detect the body temperature within the monitoring range of the camera in real time with high precision. The monitoring images and body temperature can be viewed in real time through the web client on a PC.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Manufacturer’s Declaration – Electromagnetic Emissions The medical system is intended for use in the electromagnetic environment shown below. The user shall ensure that it is used in such an environment.
of RF radiation equipment. Electrical fast transients / Bursts IEC 61000-4-4 100 kHz repetition frequency ± 2 kV for AC and DC power input ± 1 kV for input / output lines Complies AC and DC power quality should be that of a typical commercial or home healthcare, environment.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration b) Test parameter added to reflect requirement in EN 61000-6-2.
Recommended separation distances between portable and mobile RF communication equipment and the medical equipment The medical equipment is intended to be installed in an environment in which radiated RF disturbances are controlled. To minimize electromagnetic interferences, the user should maintain distances from portable and mobile RF communications equipment (e.g. transmitters) and the medical equipment and its cables as shown below.
End User License Agreement (EULA) End User License Agreement for Telethermographic System Software(EULA) Copyright © 2020 Johnson Controls. All rights reserved. Use of the software and firmware contained in this product is subject to the following End User License terms: IMPORTANT - READ THIS END-USER LICENSE AGREEMENT ("EULA") CAREFULLY BEFORE OPENING THE DISK PACKAGE, DOWNLOADING THE SOFTWARE OR INSTALLING, COPYING OR OTHERWISE USING THE SOFTWARE.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration the Software on a remote storage device on an internal network with all of the devices and may operate such component with each device over the internal network solely in the manner set forth in any accompanying documentation or, in the absence of such, solely in the manner contemplated by the nature of the Software; provided however, you must still acquire the required number of licenses for each of the
"open source" software. Such portions of the Software are governed solely by the terms of such other license, and no warranty is provided under this License for open source software. By using the Software you are also agreeing to be bound to the terms of such third party licenses.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration Controls' Position notwithstanding whether or not this is contrary to any aforementioned applicable laws or regulations, will result in automatic termination of this EULA. 5. U.S. GOVERNMENT RESTRICTED RIGHTS. The Software is Commercial Computer Software provided with "restricted rights" under Federal Acquisition Regulations and agency supplements to them. Any use, duplication or disclosure by the U.S.
a. LIMITATION OF LIABILITY. IN NO EVENT WILL JOHNSON CONTROLS'S AGGREGATE LIABILITY UNDER ANY LEGAL THEORY (INCLUDING, BUT NOT LIMITED TO, LIABILITY FOR NEGLIGENCE, STRICT LIABILITY, BREACH OF CONTRACT, MISREPRESENTATION AND OTHER CONTRACT OR TORT CLAIMS) ARISING FROM OR RELATED TO THIS EULA, OR THE USE OF THE SOFTWARE OR TELETHERMOGRAPHIC SYSTEM ON WHICH THE SOFTWARE IS LOADED (THE “DEVICE”), EXCEED THE GREATER OF USD$5.
Tyco Illustra Pro 5MP Thermal Elevated Skin Temperature Detection Camera Installation and Configuration a.
iv. visible thermal patterns are only intended for locating the points from which to extract the thermal measurement. 5. Important information describing Software’s and the Device’s performance specifications, use and calibration instructions, blackbody reference source and configuration requirements, environmental conditions, imaging distance, and system set up and installation factors is contained in the Device’s User Manual. 6.