72 8200-2007-08 A0
10 Select the Audio Playback option from the drop-down menu.
- End -
Editing a Event Action
Modify the details of an existing event action.
Procedure 80 Edit an Event Action
Step Action
1 Select Setup on the Web User Interface banner to display the setup menus.
2 Select Event Actions from the Events and Actions menu.
3 Select an entry on the event actions list, you can edit the following:
• Name
• Output - Enable/Disable
• Record - Enable/Disable
• Snapshot - Enable/Disable
• Email - Enable/Disable
• FTP - Enable/Disable
• CIFS - Enable/Disable
• Audio Playback - select the required audio clip
- End -
Alarm I / O
The cameras provide one alarm input. By connecting alarm devices, such as smoke alarms, twilight
sensors, or motion sensors to these inputs you can enhance the usability of your video surveillance
system.
For 15 seconds after being triggered, any additional individual input changes on that alarm source are
logged and do not generate any other action. This is to reduce the effect that any oscillating alarm
source, such as if a door is simply vibrating in the wind, causing a series of alarms to be generated.
Input alarms are triggered upon change of state. Either from opened to closed or from closed to open.
The camera reports the current state of each input alarms (open or closed) as well as an active or
inactive status in the alarm configuration page. Active alarms are also be visible in the current faults
page.
The triggering of any input alarm affects scheduled tasks and delay them until at least 30 seconds
has passed since the last digital alarm input was triggered.
Alarm Actions
Upon triggering each alarm input can be configured to trigger a faulty action:
• Activate the digital output contact. This stays active until the alarm is acknowledged
and cleared by an operator.
• Send an external alarm WS-Event that includes alarm details