Specifications

Setting Up Intellex Units
Configuration Guide 39
Adding, Editing, and Deleting Text Streams
1 Select an instrument from Instrument View and click Setup.
2 From the Setup dialog, click Text Streams.
3 Click Add or Edit.
4 From the Text Source tab, give the text a title in the Name field.
5 Choose a handler type from Type. Click Setup.
For General Text, enter an end-of-line delimiter to display text lines from a receipt.
For American Dynamics Printer Interface, select one or both options.
6 Select a COM Port, Bits Per Second, Data Bits, Parity, Stop Bits, and Flow Control from the
lists. For information about text, see the User’s Guide.
7 From the Camera Associations tab, select the appropriate camera(s) associated with the text
stream.
8 From the Alarms tab, click Apply selected exceptions as a group to generate an alarm:
If you selected at least one receipt definition
If a receipt definition marker is in the current receipt
If all selected text exceptions report a match for the current receipt
9 Click Build Exceptions to generate advanced text exceptions.
a Click Add to create a text exception or click Import to import a file containing text
exceptions.
b From the Advanced Text Exceptions screen, enter a name.
c Enter a match that you choose from the Transaction Data pane.
d Select Forward (default) or Backward.
Parameter Description
COM Port Select the communications port used for text stream input: comm port
associated with USB-serial adaptor.
Bits Per Second Select the text data transmission rate in bits per second (bps) at the Intellex
unit’s serial port: 110 bps to 256,000 bps. The default is 110 bps.
Data Bits Select the word size of the text data transmission stream at 7 or 8 bits. The
default size is 8 bits.
Parity Select Even, Odd or None to set the checksum bits in the text data
transmission stream. The default value is None.
Stop Bits Select the end character signal size for the text data transmission stream at 1,
1.5 or 2 bits. The default value is 1 bit.
Flow Control Select the handshake type for the text data transmission stream as Xon – Xoff,
Hardware or None. The default is None.