Specifications
Setting Up Intellex Units
34 Network Client
Setting Up Display Settings
1 From the Setup dialog, click Display.
2 From the Mode tab:
a Set the Sequence Dwell, the amount of time the unit displays a camera’s images before
switching to the next camera when you select the sequence
.
b Set the Playback to Monitor:
Yes to send Playback to the composite video output (sends live video when not in
playback).
No to use the composite video output only for live video display.
c Click Yes or No to set up the Lock Live/Playback Layout. Lock Live/Playback Layout retains
the assignment of cameras made in Playback mode when exiting to Live display mode or
reverts to the last camera assignment made in Live display mode when exiting Playback
mode. The default is No (locking disabled).
d Configure the Playback Controls: standard VCR-style control or a Jog/Shuttle style control.
e Set up the Playback Overlay, the display of information in the image area during playback.
3 Select the 2×2, 3×3, and 4×4 tabs to configure any display format:
a Select the name of the camera from the list.
b Move the mouse pointer to any location on the grid.
c Click the grid location for the selected camera. The camera’s name displays in its grid
location.
4 Click OK.
Setting Up a Call Monitor
The Call Monitor allows you to see live video from a single camera (Call mode) or from alarmed
cameras in sequence (Spot mode).
Note
You must install a Call Monitor board in the Intellex unit to use a call monitor.