3 In Linear mode, move the slider to specify the percentage of database space used before an
option message appears.
Note
Notification is only used with linear recording.
Setting Up Alarms
1 From the Setup dialog, click Alarms.
2 From the General tab, set the alarm duration.
3 Click the corresponding radio button to set:
Latch Messages—to require the operator to clear alarm messages manually from screen
using Utility > Clear Latched
Alarm on Video Loss—to generate an alarm when the unit stops receiving video signal from
any camera
Alarm Message Display—to display the ALARM message on the camera’s image when an
alarm occurs
Unit Alarm Out—to energize alarm output 16 when any alarm event occurs
Message Alert—to energize alarm output 16 when the unit is in linear mode and a notification
screen appears or unit is background archiving and a notification screen appears
15 Minute Index—to play back the video 15 minutes before an actual alarm.
Note
To use 15 Minute Index the camera must be actively recording and not in alarmed recording
mode.
4 Click the Quality tab.
a Click an option:
b Select the sensitivity and resolution. Higher sensitivity and resolution offer better quality but
less recording time.
c Click OK.
5 From the Alarms In Names tab, name each physical alarm input. Use these names when
reviewing alarm images and searching the alarm database.
6 From the Alarm Polarity tab, select the alarm polarity, the signal that triggers an alarm input.
Slider
Super highest image quality
Normal mid-range quality
Extended Record highest compression