Specifications
Configuring Network Client
Configuration Guide 15
Interpreting the Time Synchronization Log
When Network Client performs time synchronization, it generates a time synchronization message
log, which lists the unit’s name or its IP address. Use the scroll bar to view longer messages.
Setting the Live Camera Defaults
In Live Video, you can modify the live camera default settings.
1 In a camera pane, right-click and select Settings > Camera ID. Review the default settings for
the camera.
2 Select Settings > Live Camera Defaults to review the default settings for all cameras in the
video review area.
3 Adjust the image quality with the slider.
• Adjust the slider to the left during high network traffic for higher video compression,
acceptable picture quality, and decreased bandwidth usage.
Message Description
Unit did not respond within one-
minute time-out period
The Network Client successfully sent the time synchronization
command to the units, but the unit did not respond within 1
minute.
Unit user does not have privilege to
set system time
An operator logged on to a different Network Client computer
does not have the Windows security privilege for changing the
system date and time. To synchronize that computer, an operator
with this privilege must be logged on during time synchronization.
Time synchronization already in
progress from another Network
Client
The operator at another Network Client has already started a time
synchronization.
User currently updating unit date
and time
The user at the Intellex unit is updating that unit’s system date
and time.
Clock synchronized; clock was off
by more than two minutes
The unit clock is > 2 minutes earlier or later than the Network
Client’s system clock. The unit may have experienced a critical
clock problem. Even though synchronization was successful,
troubleshoot the indicated unit.
Unit is already synchronizing time Time synchronization that started from this Network Client is in
progress.
Network connection error Either a network connection could not be made to the unit or the
network connection failed.
Unidentified error Network Client cannot interpret the error message.