Installation Guide

Table Of Contents
Illustra Flex Series Installation and Configuration Guide
8200-1456-01 M0 71
2 Adjust the camera eye ball into the required position and then tighten the Torx screw.
a Pan Adjustment - Rotate the camera eye ball a maximum of +/-22°until you are satisfied
with the field of view.
b Tilt Adjustment - Tilt the camera eye ball a maximum 70° from the frontal mounting sur-
face until you are satisfied with the field of view.
Note:The arrow located near the eye ball indicates the direction of the sensor. You can also adjust
the mounting screws to assist with the camera lens position.
Note:For the Micro Dome camera series: Focus is manually set in the factory.
- End -
Procedure 36 Powering up the camera
Step Action
Connect the power cable to the power plugs as followings:
1 PoE: Connect the RJ-45 jack to a PoE compatible network device that supplies power
through the Ethernet cable.
Note:The PoE connection should be provided by a UL Listed product and the connections shall be
made in accordance with Article 800 of the NEC or local regulations.
- End -
Procedure 37 Performing a camera reboot / reset.
Step Action
1 Press and hold the reset button:
a for 1 to 5 seconds to perform a Hardware reboot / reset.
b for 5 to 20 seconds to perform a Soft Factory reset.
c for 20 plus seconds to perform a Hard Factory reset.
Note:The difference between a Soft and Hard rest is that the Hard reset clears the IP address. When
the camera is restarting it may take 2 or 3 minutes before it is fully back online and operational.