Installation Guide

Table Of Contents
Illustra Flex Series Installation and Configuration Guide
8200-1456-01 M0 57
Procedure 27 Accessing the connector pins
Refer to Figure 68 on page 57 for a pictorial index of accessing the connector pins.
Step Action
1 Remove the two screws below (1) located on the top cover to open it.
Figure 68 Accessing the connector pins
- End -
Procedure 28 Connecting the wires
Step Action
This unit supports one of the following options as power supply:
1 Connect a power source:
a AC24V wired to connector and seperate RJ45 Ethernet.
OR
b PoE through RJ45 connector.
2 Connect any optional audio or digital inputs or outputs.
Note:The power source needs to be NEC Class 2 or LPS. The Indoor (PoE+ IEEE 802.3at or 24Vac)
and Outdoor (PoE Ultra 802.3bt or 24Vac) connections should be provided by a UL Listed product
and the connections shall be made in accordance with Article 800 of the NEC or local regulations.
- End -