Installation Guide
Table Of Contents
- Overview
- Illustra Flex Series 3MP and 8MP Indoor Dome Camera
- Illustra Flex Series 3MP and 8MP Outdoor Dome Camera
- Illustra Flex Series 3MP and 8MP Outdoor Bullet Cameras
- Illustra Flex Series 3MP and 8MP Indoor Box Camera
- Illustra Flex 3MP Outdoor Compact Mini Dome Camera
- Illustra Flex Series 2MP Indoor and Outdoor IR PTZ Camera
- Illustra Flex 2MP Indoor Micro Dome Camera
- Network Topology
- Network Connection
- Configuration
- Appendix A: User Account Access
- Appendix B: Using Media Player to View RTSP Streaming
- Appendix C: Stream Tables
- Appendix D: Camera Defaults
- End User License Agreement (EULA)
Illustra Flex Series Installation and Configuration Guide
8200-1456-01 M0 144
Procedure 120 Set Scan Limits to Default Settings
Step Action
1 Select Setup on the Web User Interface banner to display the setup menus.
2 Select Scans from the PTZ menu.
3 Select the Scans tab.
The Scans tab displays.
4 Select Defaults.
The scan limits will default to Left: 0 and Right: 359.
- End -
Activating a Scan
Activate a scan on the camera, this will run using the scan limits saved in Setting Scan Limits.
Procedure 121 Activate a Scan
Step Action
1 Select Setup on the Web User Interface banner to display the setup menus.
2 Select Scans from the PTZ menu.
The Scans tab displays.
3 Select to start the video stream if it is not already active.
The video pane will display the current camera view.
(Before activating a scan, refer to the Set Scan Limits to Default Settings section on page
129.)
4 Select to activate the corresponding scan.
• Smooth -slowly pans between the left and right scan limits, starting at
the left scan limit. When the right scan limit is reached, the scan
reverses
• Stepped -pans slowly, pausing briefly every 10° between the left and
right scan limits. Once the right scan limit is reached, the scan
reverses.
• Random -pans randomly between the left and right scan limits. For
example, the scan may start at 10°, then pan right 40° and pause, pan
right 20° and pause, pan left 30° and pause, and pan right until it
reaches the right scan limit.
5 The video pane will update to display the selected scan.
6 The scan will run continuously until interrupted by a camera command, pattern, preset or
alarm.
- End -