User`s manual

Table Of Contents
DigiMux
System Information and Administration 81
RS-485 Setup
The RS-485 Setup menu allows the Administrator to set up the RS-485 unit address
and communications port. This port enables you to daisy-chain DigiMux units and
attach a remote keyboard to your system. The American Dynamics MegaPower LT
can also be connected with DigiMux units through the RS-485 communications port.
See the MegaPower LT Installation and Operation Handbook for more details.
From the Administrator Setup menu, select RS-485 Setup and press Enter. The
following menu is displayed:
Items in the RS-485 Setup menu are described in the following table:
RS-485 Setup
1 RS-485 Unit Address 009
2 RS-485 Port Settings
MENU ITEM DESCRIPTION
RS-485 Unit
Address
Allows you to change the RS-485 ID address of the DigiMux unit.
The ID is in the range of 1
to 254. The default ID is 9.
NOTE: In general, no two devices on the same RS-485 bus
should have the same ID address. Make sure device ID
assignments are unique.
If you are daisy-chaining DigiMux units, each unit must have a
unique RS-485 ID address. For example, if you daisy-chain five
units, the RS-485 ID address assignments can be 9, 10, 11, 12,
and
13.
RS-485 Port
Settings
Allows you to set up the parameters of the RS-485 port. See RS-
485 Port Settings on page 82.