User`s manual

Table Of Contents
User’s Manual
62 Advanced Operations
Event Full Screen Response
If you enable an Event Full Screen response to alarms, the alarm video is displayed in
full screen mode when an event is triggered. The full screen display of the alarm video
takes precedence over other activities (i.e., zoom, dome control, etc.) and displays on
the main monitor screen. You also must first stop the alarm or wait for the alarm
duration to expire before going into playback mode.
If the Any Key To Stop event response is enabled, press any camera key to stop the
alarm. The keys on the right side of the unit are disabled except for Menu.
If you have a call monitor, the alarm video is displayed on the call monitor. Thus, you
can continue with activities using the main screen and view the alarm event on the
call monitor as long as Event Full Screen is not enabled.
Remote
Notification
Sets up and enables remote alarm notification via DigiAlert
on a PC, E-mail, Pager, or Dialup modem. For more details,
see
Remote Notification on page 63.
Event Icon Enables (ON) or disables (OFF) the display of the Event Icon
on the Main Monitor when an alarm event occurs. The default
setting is ON.
Response
Duration
Determines the duration, or length, of the buzzer and Alarm
Out relay function after an alarm is triggered.
The value is in the range of 1 second through 999 seconds.
The default setting is 5 seconds.
Any Key To Stop If enabled (ON), you can turn the buzzer and alarm relay
responses off following an alarm by pressing any key on the
front panel. If disabled (OFF), these responses continue until
the alarm duration expires. The default setting is ON.
MENU ITEM DESCRIPTION