User`s manual

Table Of Contents
DigiMux
Advanced Operations 61
Event Response
The Event Response menu allows you to set up how the DigiMux responds to the
triggered alarm. In the Event Manager menu, move the cursor to Event Response and
press Enter. The following menu is displayed:
The items in the Event Response menu are described in the following table:
Event Response
1 Internal Buzzer ON
2 Alarm Out ON
3 Event Full Screen OFF
4 Call Event Display ON
5 Remote Notification
6 Event Icon OFF
7 Response Duration 005 sec
8 Any Key to Stop ON
MENU ITEM DESCRIPTION
Internal Buzzer Enables or disables the DigiMux internal buzzer. If set to ON,
the buzzer is activated in response to an alarm. If set to OFF,
the buzzer is not activated. The default setting is ON.
Alarm Out Enables or disables alarm output pins. Three relays are
available to provide alarm outputs to the external IO
connector. These signals can be used to drive a light or siren to
indicate an alarm event. ON enables the alarm output pins,
and OFF disables them. The default setting is ON.
Event Full Screen Enables (ON) or disables (OFF) the full screen display of
alarmed camera output. If enabled, and an alarm event occurs
on any camera input, the video from that camera is displayed
on the Main Monitor in full screen until the alarm expires. The
default setting is OFF. For more details, see
Event Full Screen
Response on page 62.
Call Event
Display
When set to ON, causes the Call Monitor to switch to the
corresponding camera when an alarm event is triggered.
When set to OFF, the Call Monitor continues to follow the
Call Monitor switching sequence during alarm events. The
default setting is ON.