User`s manual

Table Of Contents
DigiMux
Advanced Operations 45
The following table describes the parameters found in the Configuration Table:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Night: Alm In Y Y Y Y Y Y Y Y Y Night: Alm In Y Y Y Y Y Y Y
Night: Motion 2 2 2 2 2 2 2 2 2 Night: Motion 2 2 2 2 2 2 2
Wkd: Alm In Y Y Y Y Y Y Y Y Y Wkd: Alm In Y Y Y Y Y Y Y
Wkd: Motion 2 2 2 2 2 2 2 2 2 Wkd: Motion 2 2 2 2 2 2 2
Alarm Out G G G G G G G G G Alarm Out G G G G G G G
PARAMETER DESCRIPTION
Video
Used to manually disable the channels that the Administrator
does not want to display or record. Cameras are automatically
detected by DigiMux. (A = auto, N = disable, A = default). When
a channel is disabled, all related functions for that channel are
disabled in other setup menus, for example: video loss detection,
motion detection, etc. Disabled channels are skipped by the
DigiMux, so that the remaining cameras are recorded more
frequently. See
Enabling Cameras on page 46.
Covert Allows chosen inputs to be covert (invisible) on the Main
Monitor while continuing to record those inputs.
(Y
= camera covert, N = camera noncovert, N = default)
Termination Used to enable/disable the 75 termination resistor inside the
DigiMux for each camera channel (Y= termination resistor
enabled, N
= termination resistor disabled, Y = default). If the
camera loop-out connector is not in use, the termination resistor
should be enabled for correct signal termination; this is the
default condition.
Gain Control Used to set the video input gain for each camera. The value
ranges from 0 to 9. 5 is the default.
Alarm In Type Used to set the two alarm pins in the external I/O connector. An
alarm pin is set to either Alarm N.O. (Normally Open,
O
= Open) or Alarm N.C. (Normally Closed, C = Closed). The
default is O, Normally Open.
Day: Alm In Used to enable or disable each Alarm In pin during the Day
schedule (Y= enabled, N = disabled, Y
= default).