User`s manual
Table Of Contents
- DigiMux User's Manual, English
- DigiMux User's Manual, English
- Table of Contents
- Overview
- System Installation
- Basic Operations
- Front Panel Controls
- Viewing Live and Playback Video Images
- Record and Playback Operation
- Recording
- Quick Record Setting Changes
- Playback Operations
- Playback Controls
- Date/Time Video Playback
- Single Step Advance and Reversing Playback Direction
- Event List Playback
- The Event List
- Event Recording and Playback
- Pre-Alarm Availability
- The Event List Display
- Playing Back Video from the Event List
- Deleting an Event from the List in Playback Mode
- Deleting a Page from the Event List
- Covert Cameras
- Dome Control
- Dome Control Signals Installation
- Basic Alarm Features
- Advanced Operations
- System Information and Administration
- Maintenance
- Glossary
- Appendices
- Appendix A: Account Access and Priorities
- Appendix B: Connector Pin Assignments
- Appendix C: Technical Specifications
- Appendix D: Optional Connections and Installation
- Optional Connections
- Audio Connection
- IP Address Setup Information
- Dial-Up Connections via Modem
- Establishing the Dial-Out Connection: DigiMux to a PC
- Establishing the Dial-In Connection: PC to a DigiMux
- Using the Dial-Up Connections
- Connecting Extended Storage Module (ESM) Units
- Disconnecting Extended Storage Module (ESM) Units
- Additional Installation Information
- Appendix E: DigiRemote
- Appendix F: DigiMux Digital Signatures
- Appendix G: Using ControlCenter 200/300 Keyboards
- Appendix H: Troubleshooting Guide
- Index

User’s Manual
42 Advanced Operations
The following table describes the items found on the Monitor menu:
MONITOR MENU ITEM DESCRIPTION
Brightness Adjusts the brightness/darkness on monitors attached
to the unit. The range of brightness values is 0 to 63.
The default setting is 35.
Saturation Adjusts the color saturation on color monitors. This
value is ignored on monochrome monitors. The range
of saturation values is 0 to 36. The default setting is 25.
Call Monitor Dwell Sets the Call Monitor dwell time, which is the amount
of time elapsed between switching images. Unless an
alarm occurs or you select a specific monitor, the Call
Monitor shows full screen video of all installed
cameras in sequence. You can set the dwell time to a
value in the range of 1 to 255 seconds. The default
value is 3 seconds.
Call Monitor Schedule Sets the Call Monitor camera sequence.
NOTE: The Administrator’s passcode is required to
use Call Monitor Schedule.
To set a sequence, follow these steps:
1. Select a camera number for each of the 24 images
displayed in the sequence.
2. Highlight an entry with the Direction keys.
3. Press the desired Camera to assign a camera to
that location in the sequence.
4. Continue until you have completed your sequence.
A sequence can have up to 24 entries. You can select
fewer than 24 for your sequence and leave the
remaining entries blank.
The sequence can include a specific camera or cameras
multiple times. For example, to view camera 3 more
often, place camera 3 every few images in the
sequence. The sequence: 1, 2, 3, 4, 5, 6, 3, 7, 8, 9, 3, 10,
11, 12, 3 causes you to view camera 3 every three
images on the Call Monitor.
Text Color Sets the on-screen display text color. You can select one
of 8 different color schemes for text displays. The
default is 2, which displays white text for live video
and yellow text for playback.