8 System Installation
other units on the network. See IP Address Setup Information on page 122 for
information on how to set up your unit’s IP address.
It is possible to have multiple units, dome cameras, and keyboard devices installed
on the same RS-485 bus. If this is the case, make sure that each device has its own
unique address.
The ControlCenter 200/300 Keyboard requires an RJ-11 to RJ-45 adapter or
connector. If there are multiple keyboards, the first keyboard connected is
powered by the RJ-11 port, while the remaining connected keyboards must use a
separate power source.
WARNING: POWER SHOULD BE OFF BEFORE MAKING CONNECTIONS.
BASIC REAR PANEL CONNECTIONS
1. Make sure power is OFF (unit is unplugged).
2. Connect the video signal from each camera to one of the video input BNC
connectors marked Camera Input.
3. Connect the Main Monitor to the Main Monitor output of the unit (either BNC or
S-VHS connector).
4. Connect the power adapter to the DC jack at the lower right of the rear panel.
NOTE: Make sure the input voltage is DC19V, or at least 65 Watts, or the DigiMux will
not power up.
NOTE: The 4 channel and 9 channel DigiMux rear panels have 4 and 9 camera input
and camera looping out connectors, respectively.
Back panel connections are described below:
Figure 2 — 16 Channel DigiMux Rear Panel
Ethernet Main Monitor Power Jack
RS-485 Audio I/O Connector Call Monitor (BNC)
Camera Looping (1-16)
Input (1-16)
USB IEEE-1394 Main Monitor
BNC
(FireWire
®
)(RJ45) S-VHS
Ground
(RJ-11)
USB (2) USB ports for external USB devices, i.e., CD-RW or a hard disk
drive (HDD).