Specifications

18 Simplex Multiplexer
Quad Record Option
(four-camera models only)
This option allows you to record quad images rather than the
default full screen image recording. The quad image must be
displayed to record in quad mode.
ON — With quad displayed, records the quad image.
OFF — Will NOT record a quad image, or display quad in
record mode, only full-screen images sent in record mode.
The default QUAD RECORD OPTION is OFF.
Image Tenderizer
This feature dramatically reduces the shakiness associated with
high resolution compressed multicamera images. During regu-
lar operation press FUNCTION to temporarily toggle to the
other setting to decide whether to use ON or OFF.
ON — Activates the special filtering circuit when the Sim-
plex displays a multicamera image on the main monitor.
OFF — Turns off the special filtering circuit.
The default IMAGE TENDERIZER setting is OFF.
When you are finished with this menu, do one of the following:
press VCR VIEW to go to the next menu.
press FUNCTION+VCR VIEW to save the information and
leave the setup system.
VCR Record Time
NOTE: If the Simplex alarm output will not be connected to the
VCR’s alarm input, use the same settings for both VCR
RECORD TIME and VCR ALARM RECORD TIME.
This menu allows you to enter the normal (nonalarm) record-
ing speed for the VCR. Use the up and down arrow buttons to
set the speed in hours. The longer you hold the arrow button,
the faster the setting changes. You may use any setting be-
tween 1 and 999 hours.
The default setting for VCR RECORD TIME is 024 HRS.