Specifications

8 Simplex Multiplexer
Figure 5 — Rear Panel Connectors
1. gnd — Use this ground screw when connecting contact or
TTL/CMOS compatible alarm devices. See Alarms for details.
2. power — This 2.1 mm pin jack accepts the Simplex series power
module plug or other 12 VDC, center positive source of at least
1 ampere.
3. remote in — This RJ11 connector allows remote control of the
Simplex via the Remote Control Panel or using RS-232 data.
4. remote out — This RJ11 connector allows daisy chaining an-
other Simplex for use with the Remote Control Panel.
5. alarms — This DB37-S connector allows alarm activation via
contact closure or TTL/CMOS alarm inputs. It includes the
Alarm Hold Input and Alarm Output relay contacts.
6. vcr in — This BNC connector accepts composite video play-
back signal from a video recorder.
7. vcr out — This BNC connector provides a composite video sig-
nal to a video recorder.
8. call mon — This BNC connector provides a composite video
signal to the call monitor in the full screen format. The call moni-
tor only displays full-screen live images.
9. main mon — This BNC connector provides a composite video
signal to the main monitor for display in the selected format.
10. cam in — These BNC connectors accept the composite video
output of B&W or color cameras.
11. cam out — These BNC connectors provide looping camera video
from the corresponding camera input.
12.
or 75
switch — These switches allow you to set impedance
for each camera output. Set the switch to 75
to terminate it, or
set it to
if looping to other equipment.
THE REAR PANEL