Specifications
8 Simplex Multiplexer
Figure 5 — Rear Panel Connectors
1. gnd — Use this ground screw when connecting contact or
TTL/CMOS compatible alarm devices. See Alarms for details.
2. power — This 2.1 mm pin jack accepts the Simplex series power
module plug or other 12 VDC, center positive source of at least
1 ampere.
3. remote in — This RJ11 connector allows remote control of the
Simplex via the Remote Control Panel or using RS-232 data.
4. remote out — This RJ11 connector allows daisy chaining an-
other Simplex for use with the Remote Control Panel.
5. alarms — This DB37-S connector allows alarm activation via
contact closure or TTL/CMOS alarm inputs. It includes the
Alarm Hold Input and Alarm Output relay contacts.
6. vcr in — This BNC connector accepts composite video play-
back signal from a video recorder.
7. vcr out — This BNC connector provides a composite video sig-
nal to a video recorder.
8. call mon — This BNC connector provides a composite video
signal to the call monitor in the full screen format. The call moni-
tor only displays full-screen live images.
9. main mon — This BNC connector provides a composite video
signal to the main monitor for display in the selected format.
10. cam in — These BNC connectors accept the composite video
output of B&W or color cameras.
11. cam out — These BNC connectors provide looping camera video
from the corresponding camera input.
12.
∞∞
∞∞
∞ or 75
ΩΩ
ΩΩ
Ω switch — These switches allow you to set impedance
for each camera output. Set the switch to 75
ΩΩ
ΩΩ
Ω to terminate it, or
set it to
∞∞
∞∞
∞ if looping to other equipment.
THE REAR PANEL