3. The highlight appears on the 1 Pages setting. Move the Tracker Ball left or right to
change the number of pages displayed (1-16).
• Left decreases the number of pages.
• Right increases the number of pages.
4. Move the highlight to the 2 Mode setting. Move the Tracker Ball left or right to
change the mode. Table 5-2 describes the different modes; Figure 5-2 on page 5-4
illustrates the formats.
Table 5-2: Display modes
Mode Setting
0
Full-Screen
1
Picture-in-Picture (PIP)
2
2x2 (4 windows)
3
7 windows
4
9 windows
5
10 windows
6*
13 windows
7*
4x4 (16 windows)
* Not available on 10-channel multiplexers.
5. Move the highlight to the 3 Timer setting. Move the Tracker Ball left or right to
change the dwell time (1-255 seconds).
• Left decreases the dwell time.
• Right increases the dwell time.
6. Move the highlight to the page that you want to configure. Press Zoom or Focus to
select. This page displays in the mode (format) selected in step 4.
7. Set and a window selection box appear on-screen (see Figure 5-3 on page 5-5).
a. Use the Tracker Ball to select a window.
b. Enter the camera number and press
to add the camera to the window.
c. Repeat steps 7a and b until all windows are programmed. Press D to return to the
Sequence programming menu.
8. Repeat steps 6 and 7 for each page that you need to program.
Note:
You can only program the number of pages displayed on the 1 Pages
setting. For example if you select 5 in step 3, the highlight bar moves to 8
Page5 and skips to 20 Exit when the Tracker Ball moves down.
9. When finished programming, press D (or move the highlight to 20 Exit and press
Zoom or Focus) to run the programmed sequence.
5-8 ADTT16E Advanced Dome Controller Operator's Manual