Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 8 of 14
Installing with RVQX7X Quad Splitter
power
12 vdc. 1amp
alarm
remote
monitor
G1 G2
G4
vcr
G3
cam 1
cam 2
cam 3
in
out
cam 4
To Dome
Refer to instructions
included with device.
EIM #1
SensorNet
A
SensorNet B
RJ45
DB9M
Terminated
J-Box #1
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
RJ45
Primary
Touch Tracker
RVQX7X Quad Processor
(with DB9 connector)
24 Vac B
Ground
24 Vac
A
EIM Transformer
Note:
The maximum combined
SensorNet cable length is
1000 m (3000').
Note:
Only one Touch Tracker may
be installed with the dual
page Quad Splitter. This EIM
must be terminated.
Serial Cable Wiring
EIM DB9 (M) Quad DB9 (F)
2 TX 2 RX
5 Ground 1 Ground
Note:
The serial cable is not included in the kit. The
following additional parts are required:
Description Qty PN
DB9 Hood 2 2125-0007-02
DB9 Female contact pins 5 2103-0092-02
DB9 Male contact pins 5 2103-0092-01
DB9 Male connector 1 2130-0021-01
DB9 Female connector 1 2130-0022-01
DB9F
Serial Cable