Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 7 of 14
Installing with RJ45 Connection Quad Splitter
J-Box #1
To Dome
Refer to instructions
included with device.
EIM #1
SensorN
et A
SensorNet B
RJ45
DB9M
Terminated
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
RJ45
Primary
Touch Tracker
Quad Processor
(with RJ-45 connector)
24 Vac B
Ground
24 Vac A
EIM Transformer
Note:
The maximum combined
SensorNet cable length is
1000 m (3000').
Quad Splitter Interface Cable
6003-0107-01
Note:
Only one Touch Tracker may
be installed with the dual
page Quad Splitter. This EIM
must be terminated.
RJ-45 Wiring
Color Pin
Green 5
Red 4
Color Quad DB9M
Color Pin Function
Red 2 Transmit
Orange 5 Ground
Monochrome Quad DB9M
Green 3 Transmit
Orange 4 Ground
RJ45
Pin 1
Clip Up