Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 4 of 14
Installing with Quest Multiplexer
IMPORTANT! ADTT16E requires firmware 0701-2833-0103 (EEPROM)/0701-2834-0201 (Flash PROM)
or newer to work with Quest multiplexers.
Note:
Your system supports two
controllers. Terminate E1 on
the EIM that is on the end of
the SensorNet network.
To Dome
Refer to instructions
included with
device.
J-Box #1
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
EIM #1
EIM #2
SensorNet A
SensorNet B
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
RJ45
RJ45
RJ45
RJ45
Secondary
Touch Tracker
Primary
Touch Tracker
DB9M
24 Vac A
24 Vac B
Ground
24 Vac A
24 Vac B
Ground
Unterminated
Terminated
Touch Tracker - Multiplexer Cable Wiring
EIM DB9 (M) Quest Mux RJ-11
Pin Function Pin Function
2 Transmit 5 Receive B (RB)
5 Ground 4 Receive A (RA)
Quest Triplex Multiplexer
Multiplexer-Touch Tracker Cable
0652-0151-01
EIM Transformers
Note:
The maximum combined
SensorNet cable length is
1000 m (3000 ft).
RJ-11
Pin 1
Clip down
Multiplexer RJ-11 Connector Pin Assignment
Pin Definition Direction
1 - -
2 +12V External Device Power Supply Output
3 GND External Device Ground Supply Output
4 RA Input/Output
5 RB Input/Output
6 - -
6 1 6 1
RS-485