Installation guide

ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 3 of 14
Installation Diagrams
The following pages illustrate how to install the
ADTT16E advanced dome controller with different
devices:
Installing with Quest Multiplexer............................ 4
Installing with DB25 Connection Multiplexer......... 5
Installing with RJ11 Connection Multiplexer..........6
Installing with RJ45 Connection Quad Splitter...... 7
Installing with RVQX7X Quad Splitter ................... 8
Installing with Intellex 2.x DVMS and Newer.........9
Installing with RVDRP Duplex Remote Panel .... 10
Installing with Domes Only (No External Unit) .... 11
Refer to the appropriate diagram when connecting
the advanced dome controller.
Installation Notes
Depending on configuration, two advanced
dome controllers may be installed. Terminate
E1 on the EIM that is on the end of the
SensorNet network.
The maximum combined SensorNet cable
length is 1000 m (one km or 3000').
J-Box and dome wiring information is included
for information purposes only. Refer to the
appropriate installation instructions for complete
wiring information.
The ADTT16E controller requires a separate,
isolated transformer. Do not install in parallel
with a dome. Refer to Figure 1 for universal
transformer wiring information.
Figure 1: Universal Transformer wiring
information
COM
12V~
17V~
24V~
20V~
Universal Transformer EIM J3 Function
Pin 3 Ground
COM Pin 2 24Vac A
24V~ Pin 4 24Vac B