Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 2 of 14
!
Controller Installation
0351-1694-03 KIT,TTENH,ADTT16,W/RJ45&INT BX
Part Number Description Qty
6003-0047-01 CBL/A,MDR,14',8C,CROSS-PINNED 1
5899-0004-102 SCR,TCUT,M2.9X9.5,PHP,ST,Z,T1 1
2880-0083-01 ANCH,PL,W/O SCR,3/4L,#4-#6-#8 2
2816-7634-44 SCR,TYP AB,PHP,ST,Z,"8X1" 2
2109-0254-04 CON,P,EUR,.2C,28-12G,1X5P 1
2141-0002 LUG,SPADE,INSUL,22-16G,#8 STUD 3
6002-0024-01 CBL,3C,18G,CM 16.5 ft
0300-1000-01 INTERCONNECT BOX,TOUCH
TRACK
1
6003-0107-01 CBL/A,QUAD,SW,INTFCE 1
2125-0007-02 HOOD,D,9P,EMI/RFI,1/4 D CBL 1
2130-0021-01 CON,D,P,HSG,9P,NICKEL PLATE 1
2103-0092-01 CONT,P,D,26-22,AU 3
0650-1079-01 CABLE ASSY,VM8
TOUCHTRACKER/VI
1
8200-0306-02 OPS MANUAL,ADTT16E TTR 1
8200-0306-03 QUICK REF GUIDE,ADTT16E TTR 1
8000-1370-02 TTRACKER STRAIN RELIEF INSTR 1
6003-0108-01 CBL/A,VM16+/TNG,MUX/INTFCE 1
8200-0306-01 INSTALL GUIDE,ADTT16E TTR 1
RPNR00 CBL/A,RS232,10',DB9F-DB9M 1
0652-0151-01 CABLE ASSY, MUX/TOUCHTRACKER 1
8200-0306-04 PROG WORKSHEETS,ADTT16E TTR 1
For Quad Splitter (RVQX7X) with DB9 Connector
These additional parts are required.
PN Description Qty
2125-0007-02 DB9 Hood 2
2103-0092-02 DB9 Female contact pins 5
2103-0092-01 DB9 Male contact pins 5
2130-0021-01 DB9 Male Connector 1
2130-0022-01 DB9 Female Connector 1
WARNING: RISK OF ELECTRIC
SHOCK! Disconnect AC Power to
the switch.
CAUTION-Electrostatic Sensitive
Device: Follow proper handling
procedures to prevent component
failure.
Note: Before installing the ADTT16E advanced
dome controllers, identify the type of external unit
that will be connected, if applicable. Build any
cables that are required. Refer to the Installation
Diagrams starting on page 3 for specific
instructions.
1. Terminate the External Interconnect Module
(EIM) at the end of the SensorNet network. If
more than one advanced dome controller will be
installed, one EIM will be terminated; the other
EIM will be unterminated. Refer to the
appropriate wiring diagram for your
configuration.
2. Mount each EIM on a wall or other surface
within 3m (10 feet) of the controller.
3. Connect the power transformer and SensorNet
cable to J3 on each EIM. If two controllers will
be installed, connect the SensorNet cable from
the first EIM to the second EIM.
4. Depending on the external unit that will be
attached to your system, connect the
appropriate cable to the DB9 connector on the
EIM. Refer to the appropriate wiring diagram for
additional details.
5. Connect the data cable from J1 on the Primary
controller’s EIM to the remote port on the
external unit. Refer to the appropriate wiring
diagram for additional details.
6. Connect the modular cable from J2 on each
EIM to the controller.
7. Connect the SensorNet cable from the dome to
the first EIM. Refer to the appropriate wiring
diagram for additional details.
8. Plug the power transformer into a grounded,
3-wire receptacle.
Note: If the keypad and backlighting do not
illuminate when power is applied, unplug each
power transformer and repeat steps 3 through 8.
Continue with Configuring the External Device.
!