Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 13 of 14
Additional Tasks
The following maintenance functions can be
performed using the advanced dome controller.
When using the menus, pressing Zoom selects the
first line of the LCD; pressing Focus selects the
second line of the LCD.
Displaying System Information
This procedure allows you to display system
information about the advanced dome controller
you are using.
1. Press Menu.
2. Scroll through the menu items until
Show System Info appears on the LCD.
Press Zoom or Focus.
The following system information is available:
− Unit Type: Primary or Secondary
− ROM Checksum Values
− Calibration information (display should read
all 0)
− Product Code Flash Version
− Product Code EEPROM Version
3. Press Next or Previous to scroll through the
information.
4. Press Menu when finished reviewing the
system information.
Performing the SensorNet Ping
Test
This procedure tests communications between the
advanced dome controller and other SensorNet
devices (domes or other controller).
1. Press Menu.
2. Scroll through the menu items until Ping
Dome/TTR appears on the LCD. Press Zoom or
Focus to select.
3. The LCD displays the dome communication
(ping) test information.
4. Press Next to display the controller ping test
information.
5. Make note if any of the tests fail. Press Menu to
exit.
Note: Off-line domes or fixed cameras will
generate a warning beep and not permit the use of
the Ping test.
Resetting a Dome
This feature allows you to reinitialize a SpeedDome
series camera dome.
1. Use the number buttons to the select the dome
to reset then press
(Camera button).
2. Press Menu.
3. Scroll through the menu items until
Reset Dome appears on the LCD. Press
Zoom or Focus to select.
The advanced dome controller sends a request to
the selected dome to reboot. After a brief delay, the
controller resumes camera control mode.
Adjusting V-Phase
Use this procedure to adjust the vertical phase for
cameras installed with your system.
1. Press Menu.
2. Scroll through the menu items until Adjust
V-phase appears on the LCD. Press Zoom or
Focus to select.
3. Press Next or Previous to observe V-phase
through the oscilloscope or Fluke scope.
4. When you are satisfied with the setting, press
Menu to exit.
Note: Off-line domes or fixed cameras will
generate a warning beep and not permit the use of
the V-phase utility.