Installation guide
ADTT16E ADVANCED DOME CONTROLLER 8200-0306-01, REV. C
INSTALLATION GUIDE 10 of 14
Installing with RVDRP Duplex Remote Panel
IN
OUT
Note:
Your system supports two
controllers. Terminate E1 on
the EIM that is on the end of
the SensorNet network.
To Dome
Refer to instructions
included with device.
J-Box #1
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
EIM #1
EIM #2
SensorNet A
SensorNet B
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
RJ45
RJ45
RJ45
RJ45
Secondary
Touch Tracker
Primary
Touch Tracker
DB9M
24 Vac A
24 Vac B
Ground
24 Vac A
24 Vac B
Ground
Unterminated
Terminated
EIM DB9 Wiring
Color Pin Function
Red 2 Transmit
Black 5 Ground
Note: Green wire is not used.
Remote Duplex Mux (RVDRP)
(Rear View)
Multiplexer Interface Cable
6003-0108-01
EIM Transformers
Note:
The maximum combined
SensorNet cable length is
1000 m (3000 ft).
RJ11
Note:
The Touch Tracker always
connects to the last output of
the remote multiplexers.
4-conductor Straight-Thru RJ-11 Cable
6003-0106-01
Note:
Both ends of RJ-11 cable connect
to the
p
orts labeled “Data In”
Multiplexer