Specifications

30
MegaPower LT
Creating Responses
Using the Response Set Up screen it is possible to create responses, which can be
linked to the triggering of an alarm input or the receipt of a network event from another
matrix.
For example, when an alarm input is triggered, a response can be programmed for the
MPLT to output a message to an alram monitor, switch to a preset position on a specified
camera, activate one or more of the auxiliary outputs, generate an audible sound from the
keyboards or to generate a network event that can be sent to other units in the network.
Up to 32 responses can be programmed to respond to up to 32 alarms or up to 255
events.
To program/change response settings, follow the steps below:
1. In the Alarm menu, select the Response Set Up option.
2. In the Response Set Up screen, use the numeric keys to enter the Response
number to be programmed/changed.
3. Move to the Title option. This field is used to specify a title for the response.
4. Use the joystick to amend the title. Highlight the title so it flashes, then select the
keyboard enter key, select the character to be edited using left/right joystick commands
and edit the selected character using up/down joystick commands. Use the SHIFT
(
) key in conjunction with up/down joystick commands to change between upper
and lower case.
5. Move to the Switch to camera option.
6. Use the numeric keys to enter the camera input to be displayed on the alarm monitor
when the response is triggered. Enter 0 if no camera input is to be displayed.
7. Move to the Camera preset option.
8. Use the numeric keys to enter the preset number that the camera is to move to when
the response is triggered. Enter 0 if no preset is to be recalled.
9. Move to the Generate event option.
10.Use the numeric keys to enter which network event is to be generated when the
response is triggered. Enter 0 if no event is to be generated.
11. Move to the Activate relays option.
5.7 Response Set Up
Response number :01
Title :
RESPONSE 1
Switch to camera :01
Camera preset :00
Generate event :255
Activate relays :1 ONLY
Generate sound :SHORT
Return to Alarm Menu