7 Enter Poll Period
Note
1. When configuring a non-zero Polling Period, non-zero values should be set for
TimeOut Delay and Comm Fail Delay times
2. When configuring a zero Polling Period, zero should also be set for TimeOut
Delay and Comm Fail Delay times
8 Enter the poll command in the Poll Command textbox. This is a stream of bytes, usually
set by the device manufacturer, sent on a regular basis to the device to maintain
communications
9 Enter Poll Command Acknowledge. This is the expected response from the device
which is sent back to victor as acknowledgment of the poll message
10 The Journal Unknown Message checkbox is deselected by default. To enable, select the
checkbox
Note
Enabling Journal Unknown Message means that any message received by the
victor General Purpose server component that does not match an existing
protocol will be sent to the activity viewer. When disabled, unknown messages are
ignored
11 Select either Serial Port or Network Port
If Serial Port is selected:
a Enter Communication Port
If Network Port is selected:
a Enter IP Address
b Enter Communication Port
c Enter Reconnection Period
12 Enter TimeOut Delay Time in 1/10th seconds
13 Enter Comm Fail Delay time
14 Enter Header Character
15 Enter Trailer Character
Note
Trailer Character is mandatory.
16 Enter Message Resend Count
17 Enter Max Buffer Size
18 Expand Alerts section
19 Select to add an alert
20 Select Property from the drop down menu
21 Select Value from the drop down menu
22 Select then select an Action from the Object Selector