Specifications
Operators
115
Remotely Log Operator Out of Workstation
Operators can be remotely logged out of particular workstations on the network.
Procedure 17-3
Remotely Log Operator Out of Workstation
Step Action
1 Select Devices from the Home tab
2 Select next to Workstations to expand the selection
3 Right click the workstation you wish to log the operator out of
4 Select Log Operator [operator username] Out. Warning dialog opens, prompting
confirmation of the logout
5 Select Yes to log the operator out, or No to cancel
- End -
Change Single Sign-on Value
The log-in window will display at client start up only when the Single Sign-on option is set to
‘False’; with Single Sign-on set to ‘True’, the Login window is bypassed and the server will rely on
the current windows identity credentials from the Windows OS to establish a client connection.
This procedure describes how to change single sign-on values between ‘true’ and ‘false’.
Note
Depending on your UAC settings on Windows 7 the following procedure may vary slightly, you
may be notified or asked for permission to continue before making changes to the file.
Procedure 17-4
Change Single Sign-on Value
Step Action
1 Navigate to ACVS.Enterprise.Client.Core.Host.exe.config file on the client machine.
The default location for this file is C:\Program Files\Tyco\victorClient.
2 Right click the ACVS.Enterprise.Client.Core.Host.exe.config file.
3 Select Open. Message displays informing Windows cannot open this file.
4 Select Select a program from a list of installed programs.
5 Select OK. Open with...dialog box displays.
6 Select WordPad from the program list.
7 Select OK. File opens as a text document.