Specifications

SECURITY CAMERA SYSTEM UPGRADE AND REPLACEMENT
FOR MONTGOMERY COUNTY DETENTION CENTER
SECURITY CAMERA SYSTEM 17000-50
F. An RS-232 input shall also be provided for cascading multiple code distributors
and/or alarm interface units. For ease-of-connection, a pair of 8-pin modular RJ-
45 connectors and associated cables shall be provided. The RS-232 output shall
be compatible with three wire, 18 AWG, shielded-wire for a distance of up to
300 meters (1000 feet).
G. The code distributor shall be capable of storing up to 16 presets for suitably
equipped SpeedDome Ultra or SpeedDome Optima programmable camera domes.
H. The code distributor shall be an American Dynamics AD2083-02B (120 VAC),
ADS2083-02B-1 (230 VAC) or equivalent.
I. The code distributor must meet the following operating requirements:
1. Operational
Dome outputs: 16 RS-422 total, four independent groups of four connectors
Address Ranges: 11 blocks of 99, maximum address 1024
Presets: Stores up to 16 presets per suitably equipped SpeedDome
Ultra or SpeedDome Optima dome
Dome Alarms: Up to four (on suitably-equipped domes transmitted over
dome data cabling) transmitted at 1200, 2400, 4800, or
9600 baud
Alarm Output:RS-232 via RJ-45 direct connection to system CPU
Alarm Indication: LED and Form-C relay outputs
Diagnostic LEDs: Power, alarm and control code status
2. Connectors
High Speed Data Line: BNC, in/out
Manchester Control Code: One 12-pin removable “euro style” screw terminal
strip for black, white and shield connection
RS-422: Eight 12-pin removable “euro-style” screw
terminals strips
Four groups of four, with +, - and ground
connections of transmit and receive
RS-232: RJ-45 in/out, cascadable
Two, 8-pin modular
Alarm output: Form C outputs
3. Electrical
Supply Voltage:
AD2083-02B: 120 VAC (50/60 Hz)
ADS2083-02B-1: 230 VAC (50/60 Hz)
Power Consumption: 8 watts (nominal)