Specifications

SECURITY CAMERA SYSTEM UPGRADE AND REPLACEMENT
FOR MONTGOMERY COUNTY DETENTION CENTER
SECURITY CAMERA SYSTEM 17000-45
c. Minimum per System: 128,000
10. Monitor Output
Video OutputsAC coupled, zero volts DC
On-Screen Displays Time, Date, Site Number, Site Title, Video Input Number, Video
Input Title, Monitor Status, Camera Status (all titles are 16 characters,
user definable)
Time 24-hour clock
Date Selectable formats MM-DD-YY, DD-MM-YY, YY-MM-DD
Status Alarm, Dwell Time, Hold
Display Format White characters with black outline, height of 9 TVL
Display Position Adjustable for both horizontal and vertical position and brightness
control.
User on/off control of camera number, title and/or date and time
11. Alarms
Alarm Call-up 4096 alarm inputs
Programmable to call any video input or salvo (zone) to monitors
Programmable to initiate any preset or auxiliary output relay
Alarm Display Modes:
Auto Sequence sequences multiple alarms until cleared
Auto Hold displays initial alarm until cleared, queues
subsequent alarms
Sequence and Display Earliest alarm is displayed on one monitor until
cleared, subsequent alarms are sequenced on a
second monitor
Block Auto SequenceAlarms are sequenced on blocks (groups) of monitors; a
block consists of up to 16 contiguous monitors
Block Auto Hold Alarms are displayed on blocks of monitors,
subsequent alarms are queued; multiple blocks may
be defined
Alarm Clearance Modes:
Acknowledge Operator removes alarms manually from a keyboard
Instant Auto Clear Removes alarms when the alarm input clears or when
acknowledged from a system keyboard
Instant Auto Clear/
No Manual
Acknowledgment Removes alarms when the alarm input clears only
Auto Clear Removes alarms approximately 20 seconds after the alarm
input or when acknowledged from a system keyboard
Auto Clear/
No Manual
Acknowledgment Removes alarms approximately 20 seconds after the alarm
input only