SECURITY CAMERA SYSTEM UPGRADE AND REPLACEMENT
FOR MONTGOMERY COUNTY DETENTION CENTER
SECURITY CAMERA SYSTEM 17000-44
b. Baud Rate 1200, 2400, 4800, 9600, 19,200 and 38400
selectable
c. Control Switching Keyboard/Receiver: 20 milliseconds
d. PC System Software MS Windows graphical user interface
software program compatible with Microsoft Windows XP and
2000. Simplified system setup, archiving and retrieval of system
data, and uploading and downloading of setup information to the
system
6. Site Control: Control of fixed or variable speed pan/tilts, motorized zoom
lenses, domes, recorders, auxiliary relay outputs and preset program and
recall of suitably equipped devices.
7. Management Control:
a. System Passwords 64 user programmable
b. Priority Eight levels
Keyboard override
Lockout of camera site
Access to programming menus
c. Partitioning Keyboard to monitor access
Keyboard to camera view
Keyboard to camera control
Camera to monitor access
Monitor to camera access
8. Tours:
a. Individual Monitor Tours - One tour per system output, 64
entries per tour
b. Universal System Tours - 64 universal tours, 64 entries per tour,
selectable to any system output, cascadeable for sequences greater
than 64 cameras.
c. Individual Camera Dwell - 1–60 seconds (adjustable) for both
Monitor Tours and Universal System Tours
d. Salvo (Zone) Tours - Multiple video inputs called to
multiple contiguous monitors simultaneously, 64 individual camera
groups consisting of 16 cameras each, automatic and manual
operation.
e. Tour Activation - Automatic 35 user programmable time slots per
day, independently programmed for each of seven days
9. Macros
:
a. Initiates a series of user-defined events
b. Minimum per Keyboard: 1000