Specifications
SECURITY CAMERA SYSTEM UPGRADE AND REPLACEMENT
FOR MONTGOMERY COUNTY DETENTION CENTER
SECURITY CAMERA SYSTEM 17000-31
C. Related Work Specified Elsewhere:
1. The work of this Section is related to the work of the following sections:
a. General Provisions
b. System Description and Integration
c. Closed Circuit Television System
D. Reference Specifications, Materials, and/or Codes:
1. National Electrical Code
E. Submittals:
1. General: Submittals shall be made in accordance with the General
Provisions (Section 17000) of these specifications.
2. Specific Requirements:
a. Submit a listing or catalog cuts for all equipment and devices
being furnished under this Section.
b. Submit drawings of all control screens to designate colors and
icons for each condition.
c. Submit electronic files from which each screen may be viewed to
reflect selected colors and icons. Software shall be provided to
allow Engineer and Owner to review files employing AutoCad
2000 to view the screens.
3. Software Development
a. Within one (1) month of receiving the approved shop drawing
submittal, the security equipment contractor shall schedule a
preliminary meeting with the Owner and Engineer.
b. Specific operation and function of the security control system must
be determined prior to the preliminary meeting. Extensive analysis
outlining all performance of software design and application will
be determined and approved at the preliminary meeting.
c. The security equipment contractor shall prepare a detailed report,
summarizing all software design and function criteria to be
delivered to Engineer, owner, and software engineer no later than
three (3) weeks from the date of the preliminary meeting. The
custom software that runs the security control system shall be
designed specifically from this document.