Specifications
SECURITY CAMERA SYSTEM UPGRADE AND REPLACEMENT
FOR MONTGOMERY COUNTY DETENTION CENTER
SECURITY CAMERA SYSTEM 17000-11
a. Submittals shall be marked to show specification reference
including the section and paragraph numbers.
b. Submit each section separately.
8. The submittals shall include the following:
a. The documents indicated under qualifications in this section.
b. Technical information for all materials and equipment. Information
must confirm compliance with contract requirements. Include the
manufacturer's name, model or catalog numbers, catalog
information, technical data sheets, shop drawings, pictures,
nameplate data and test reports as required.
c. If equipment cabinets are changed – provide equipment room
layouts in plan and elevation views, all equipment, cabinets, and
wireways. Each cabinet must be labeled.
d. If equipment cabinets are changed – detailed equipment cabinet
assembly drawings. Cabinet details must show each piece of
equipment, including surge protection, fuses, relays and terminal
strips. All wiring terminals must be labeled on the drawings to
indicate the field devices, communications lines, or power supplies
connected to them.
e. Elementary and interconnection wiring diagrams for
communication and signal systems, control system and equipment
assemblies.
f. Functional diagrams of the integrated system and of subsystems.
g. Functional descriptions of the system hardware and software,
specifically related to the functional diagrams and the system
integration.
9. Documents will not be accepted or considered unless:
a. They comply with the requirements of the General Conditions.
b. They include complete information pertaining to appurtenances
and accessories.
c. They are submitted as a package where they pertain to related
items.
d. They are properly marked with service or function identification
as related to the project, where they consist of catalog sheets