Specifications

INSTALLATION AND SERVICE GUIDE
DeltaDome II Camera Dome
8000-2708-01, REV. B
36
Specifications-Indoor Dome
Operational
Pan/Tilt:
Manual Pan/Tilt Speed ....... 1°-100° per second
(scaled to zoom position)
Preset Pan/Tilt Speed......... 220° per second
maximum
Pan Travel.......................... 360° continuous rotation
Tilt Travel............................ >90°
Pan/Tilt Accuracy................ ±0.5°
Zoom:
Optical Zoom...................... 22X
Digital Zoom ....................... 8X
Zoom Pause....................... 22X or 33X (default)
Zoom Stop.......................... 33X, 44X, 55X, 66X, 77X,
88X (default), 99X, 110X,
121X, , 132X, 143X,
154X, 165X, 176X
Zoom/Focus Accuracy........ ±0.5%
Auto Synchronization:
Line Locked........................ Remote V-phase
adjustment
Internal ............................... Built-in sync generator
Address Range ...................... 1-255
Number of Presets:
VM16 / ADTT16 .............. 96 with SensorNet 485
VM32 / AD32 .................. 96 with SensorNet 485
AD2150........................... 64 with Manchester
16 with RS422*
VM96 .............................. Virtual with RS422 or
SensorNet 485
VM168 / AD168 .............. 64 with Manchester,
RS422, or SensorNet
16 with RS422*
AD2050........................... 64 with Manchester
16 with RS422*
Acquisition Time..................... <1 second to position at
60% of zoom setting
Programmable Patterns ......... 3
Program Storage.................... 256 Kbytes of Flash
memory
Data Storage.......................... 128 Kbytes of SRAM
Menu Languages ................... English, French, German,
Spanish, Italian, and
Portuguese
* Using AD2083-02A
Electrical
Input Voltage ........................ 24-30 Vac, 50/60 Hz
UL Class 2 LPS
Design Tolerance ................. 16-36 Vac, 50/60 Hz
Current ................................. 0.85 A max.
Power On In-Rush Current... 1.5 A
Surge Protection:
Video Output ........................ 100 A
Power Line ........................... 60 V, 1.5 joules, 250 A
RS422 .................................. 5.6 V, 0.1 joules, 40 A
Manchester/
SensorNet 485 ..................... Isolated transformer
coupled, 10 kA impulse
rated gas tube
Alarm Inputs ......................... 5.6 V, 0.1 joules, 40 A
Alarms Inputs/Control Outputs:
When no I/O board is used:
Inputs ............................ 1 dry contact/3.5 mA sink
Outputs.......................... 1 open collector driver
@ 12 Vdc, 40 mA
When I/O board is used:
Inputs ............................ 4 dry contacts/3.5 mA sink
Outputs.......................... 4 open collector drivers
@ 12 Vdc, 40 mA
Environmental
Operating Temperature ........ –10° to 50°C (14° to 122°F)
Relative Humidity.............. 0 to 95% non
-condensing
Mechanical
Height................................... 20.8 cm (8")
Diameter............................... 12 cm (4.7")
Weight: .................................
Housing and Eyeball......... 1.18 kg (2.6 lbs.)
Base (standard) ................ 0.09 kg (.20 lbs.)
Base (with I/O board)........ 0.16 kg (.35 lbs.)
Lens and Bubble Densities
Eyeball Lens......................... f0
Bubbles:
RUCLR (Clear).................. f0
RUSLV (Silver).................. f1.5 to f2
RUSMK (Smoke) .............. f0.5
RUGLD (Gold) .................. f1.5 to f2