2033 Auxiliary Follower Installation and Operating Instructions The 2033 Auxiliary Follower can be used with all American Dynamics Matrix Switching Systems employing control code(s). The 2033 Auxiliary Follower is used to provide a relay closure when an auxiliary or alarm command has been issued. Other uses include the operation of panel displays showing called or alarmed camera sites.
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished by SENSORMATIC is believed to be accurate and reliable.
AMERICAN DYNAMICS The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Table of Contents Description ............................................................ 1 Features ................................................................. 1 Installation............................................................ 2 Mounting......................................................2 Auxiliary/Camera Select..............................2 DIP Switches................................................2 Connections Relay Connections .....................................
DESCRIPTION AA AA SELECT 1 5 DATA LINE 9 13 GROUP 1 POWER DATA LINE ABCDE F 2A B AB AB AB 17 AB AB ABCDE F 19 ABCDE F B20 WS AB AB 10 AB 21 3 18 ABCDE F GROUP 2 A6B AB AB 4 AB AB AB AB 25 11 7 22 AB AB AB AB AB AB 26 AB 12 IN 14 AB AB AB 29 15 30 AB AB OUT AB AB A B 16 31 27 G1 IN G1 OUT G2 IN G2 OUT 8 23 AB 24 28 AB AB 32 AB 120V 60HZ AB Figure 1 - 2033 Auxiliary Follower The 2033 filters the incoming codes for auxiliary commands and camera gr
INSTALLATION For optimum performance, the 2033 should be located near the Switching Systems (1995, 1996, 2050, or 1024) or near the Control Code Line of a Matrix Switching System. Avoid heat sources or poorly ventilated racks. IF YOU ENCOUNTER ANY PROBLEMS OPERATING THIS UNIT, OR NEED TECHNICAL ASSISTANCE, CALL OUR SERVICE CENTER.
CONNECTIONS CONNECTIONS Relay Connections Two groups (GROUP 1 and GROUP 2) of four 12-pin connectors are provided on the rear panel. Each group provides connection for double pole relays. The two groups provide 32 pairs of relay closures. Relay contact ratings are 24 VAC, 0.6 A resistive load, 2 Amp, 30VDC. Power through the relays is not supplied by the 2033.
CONNECTIONS Control Code lines must be terminated in 120 ohms. Check the last unit on each line to ensure that 120-ohm termination is present. Intermediate units on a Control code line must not have 120-ohm termination. To remove the termination of the 2033 code line, jumper J32 must be removed from the main PCB. Data Line Connections (1995 or 1996) A DATA LINE is connected from the DATA LINE OUT BNC on a Matrix Bay to the DATA LINE IN BNC on the rear panel of the Auxiliary/Alarm Follower.
OPERATION 2033 B W S 2033 B W S 2033 B W S Power Sources The 2033 Auxiliary Follower does not contain an On/Off Switch. The socket outlet shall be located near the equipment and shall be readily accessible. The 120 V units are supplied with a pendant 3-wire cord and plug for mating to the primary source outlet. The 230 V units are supplied with a Euro style IEC 320 type inlet. A suitable detachable cord should be connected between the IEC 320 inlet and the power source.
APPENDIX
2033 AUXILIARY FOLLOWER Camera # 1 Channel B Channel A 1 A B 2 3 4 A B A B A B DATALINE/LAN FROM CPU (1995,1996) Selects Auxiliary # and Camera Group # to Follow SELECT GROUP 1 PWR DATA GROUP 2 ON 5 ABCDEF 6 9 7 10 8 13 11 14 DATA LINE 15 12 ON ABCDEF A B A B A B 18 A B A B 2119 A B A B 22 20 A B A B 25 23 A B A B 26 24 A B A B 29 27 A B 30 A B 1 28 31 OUT 32 ABCDEF A B OFF ON A B 17 OFF ON 16 IN OFF A B A B A B A B A B A B A B A B A B A
TYPICAL SYSTEM CONNECTIONS 2033 AUXILIARY FOLLOWER RELAY ALARMS -CODE- CAMERAS 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 MONITORS 1 2 1 3 4 2 5 KEYBOARDS 3 2 3 4 5 RS232 PORTS 2150 BWS RS-232 1 MONITOR MONITOR MONITOR MONITOR 8 6 4 2 7 5 3 1 2 3 4 A A A A A A A A B B B B B B B B O U T O U T O U T O U T O U T O U T O U T O U T J1 OUT B W S 1650 1650A from 1600, 1650A, 1700, or
TYPICAL SYSTEM CONNECTIONS 2033 AUXILIARY FOLLOWER SELECT 5 ABCDEF ON GROUP 1 6 8 OFF ABCDEF A B ABCDEF 17 20 A B A B A B A B A B A B A B 9 12 7 A B A B 10 A B 13 11 16 A B A B DATA LINE 15 14 IN A B A B A B 1 ON PWR OFF DATA 18 2119 24 22 25 23 28 26 29 27 32 30 31 OUT ON GROUP 2 A B OFF A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B G1 IN G1 OUT G2 IN G2 OUT ABCDEF ON OFF A B BWS A B A B A B 2033 BW S CODE LED WBS J1 1691
TYPICAL SYSTEM CONNECTIONS 2033 AUXILIARY FOLLOWER with 1650 RS-232 1 SYNC VIP MONITOR MONITOR MONITOR MONITOR 8 6 4 2 7 5 3 1 2 1 A A A A A A A A B B B B B B B B O U T O U T O U T O U T O U T O U T O U T O U T 3 3 4 5 7 J1 OUT 1650: MONITORS 1 - 8 2 4 6 8 POWER AND SIGNALS VIP CAMERA 4 J1 OUT B W S CAMERA CAMERA CAMERA CAMERA CAMERA 57 49 41 33 25 17 9 1 3 58 50 42 34 26 18 10 2 5 59 51 43 35 27 19 11 3 7 60 52 44 36 28
DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and EN45014 Manufacturer’s Name: Sensormatic Electronics Corporation Manufacturer’s Address: 1 Blue Hill Plaza 2nd Floor Pearl River, New York, 10965 USA Declares, that the product listed below: Name/Type: Auxiliary Follower Model Number: AD2033-1 complies with all applicable directives as demonstrated by conformance to the following Product Specifications: Safety: EN 60950: 1992 EMC: EN 50130-4: 1995 EN 55022: 1994 , Class B EN 61000-3-2:
SPECIFICATIONS Electrical Ratings: AD2033 AD2033-1 120 VAC, 50/60Hz, 15 W 230 VAC, 50/60Hz, 125 mA Relay Contact Ratings: 0.6 A, 24 VAC; 2 A, 30 VDC Mounting: Surface Mount or Rack Mount Weight: 7 lbs (1.4 kg) Finish: Shadow Gray Dimensions: 17" W x 3.